m+Medelevator.RU
← Поиск публикаций
International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2023

Therapeutic dose and long-term efficacy of high-intensity focused ultrasound ablation for different types of uterine fibroids based on signal intensity on T2-weighted MR images.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wang Yangyang, Gong Chunmei, He Min, Lin Zhenjiang, Xu Feng, Peng Song, Zhang Lian

Аннотация

OBJECTIVE: To investigate the therapeutic dose and long-term efficacy of high-intensity focused ultrasound (HIFU) ablation for different types of uterine fibroids based on signal intensity on T2-weighted MR images (T2WI).

MATERIALS AND METHODS: Four hundred and one patients with a solitary uterine fibroid treated with HIFU were classified into four groups consisting of extremely hypointense, hypointense, isointense and hyperintense fibroids. Each group was further classified into two subtypes: homogeneous and heterogeneous, based on signal homogeneity of fibroids. The therapeutic dose and long-term follow-up results were compared.

RESULTS: There were significant differences in treatment time, sonication time, treatment intensity, total treatment dosage, treatment efficiency, energy-efficiency factor (EEF) and non-perfused volume (NPV) ratio among the four groups (p<.05). The average NPV ratio achieved in patients with extremely hypointense, hypointense, isointense and hyperintense fibroids was 75.2 ± 14.6%, 71.1 ± 15.6%, 68.2 ± 17.3% and 67.8 ± 16.6%, respectively; the re-intervention rates at 36 months after HIFU were 8.4%, 10.3%, 12.5% and 6.1%, respectively. Sonication time, treatment intensity and total energy for heterogeneous fibroids were greater than that for homogeneous fibroids in patients with extremely hypointense fibroids (p<.05). The treatment time for heterogeneous fibroids was significantly longer than that for homogeneous fibroids in patients with isointense fibroids (p<.05). Multivariate ordered logistic regression analysis showed that the ablation volume of fibroids and treatment time were related to NPV ratio (p<.05).

CONCLUSION: Every group of patients obtained satisfactory long-term results. Hyperintense fibroids are difficult to treat by HIFU. Heterogeneous fibroids are more difficult to treat with HIFU than homogeneity fibroids.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты