m+Medelevator.RU
← Поиск публикаций
Insights into imaging · 2023

Deep learning enables automated MRI-based estimation of uterine volume also in patients with uterine fibroids undergoing high-intensity focused ultrasound therapy.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Theis Maike, Tonguc Tolga, Savchenko Oleksandr, Nowak Sebastian, Block Wolfgang, Recker Florian, Essler Markus, Mustea Alexander, Attenberger Ulrike, Marinova Milka, Sprinkart Alois M

Аннотация

BACKGROUND: High-intensity focused ultrasound (HIFU) is used for the treatment of symptomatic leiomyomas. We aim to automate uterine volumetry for tracking changes after therapy with a 3D deep learning approach.

METHODS: A 3D nnU-Net model in the default setting and in a modified version including convolutional block attention modules (CBAMs) was developed on 3D T2-weighted MRI scans. Uterine segmentation was performed in 44 patients with routine pelvic MRI (standard group) and 56 patients with uterine fibroids undergoing ultrasound-guided HIFU therapy (HIFU group). Here, preHIFU scans (n = 56), postHIFU imaging maximum one day after HIFU (n = 54), and the last available follow-up examination (n = 53, days after HIFU: 420 ± 377) were included. The training was performed on 80% of the data with fivefold cross-validation. The remaining data were used as a hold-out test set. Ground truth was generated by a board-certified radiologist and a radiology resident. For the assessment of inter-reader agreement, all preHIFU examinations were segmented independently by both.

RESULTS: High segmentation performance was already observed for the default 3D nnU-Net (mean Dice score = 0.95 ± 0.05) on the validation sets. Since the CBAM nnU-Net showed no significant benefit, the less complex default model was applied to the hold-out test set, which resulted in accurate uterus segmentation (Dice scores: standard group 0.92 ± 0.07; HIFU group 0.96 ± 0.02), which was comparable to the agreement between the two readers.

CONCLUSIONS: This study presents a method for automatic uterus segmentation which allows a fast and consistent assessment of uterine volume. Therefore, this method could be used in the clinical setting for objective assessment of therapeutic response to HIFU therapy.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты