MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.mri.2016.10.028

Медицинская библиотека · Magnetic resonance imaging · 2016

A fast screening protocol for carotid plaques imaging using 3D multi-contrast MRI without contrast agent.

Zhang Na, Zhang Lei, Yang Qi, Pei Anqi, Tong Xiaoxin, Chung Yiu-Cho, Liu Xin

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To implement a fast (~15min) MRI protocol for carotid plaque screening using 3D multi-contrast MRI sequences without contrast agent on a 3Tesla MRI scanner.

MATERIALS AND

METHODS

7 healthy volunteers and 25 patients with clinically confirmed transient ischemic attack or suspected cerebrovascular ischemia were included in this study. The proposed protocol, including 3D T1-weighted and T2-weighted SPACE (variable-flip-angle 3D turbo spin echo), and T1-weighted magnetization prepared rapid acquisition gradient echo (MPRAGE) was performed first and was followed by 2D T1-weighted and T2-weighted turbo spin echo, and post-contrast T1-weighted SPACE sequences. Image quality, number of plaques, and vessel wall thicknesses measured at the intersection of the plaques were evaluated and compared between sequences.

RESULTS

Average examination time of the proposed protocol was 14.6min. The average image quality scores of 3D T1-weighted, T2-weighted SPACE, and T1-weighted magnetization prepared rapid acquisition gradient echo were 3.69, 3.75, and 3.48, respectively. There was no significant difference in detecting the number of plaques and vulnerable plaques using pre-contrast 3D images with or without post-contrast T1-weighted SPACE. The 3D SPACE and 2D turbo spin echo sequences had excellent agreement (R=0.96 for T1-weighted and 0.98 for T2-weighted, p<0.001) regarding vessel wall thickness measurements.

CONCLUSION

The proposed protocol demonstrated the feasibility of attaining carotid plaque screening within a 15-minute scan, which provided sufficient anatomical coverage and critical diagnostic information. This protocol offers the potential for rapid and reliable screening for carotid plaques without contrast agent.

Для цитирования: Zhang Na, Zhang Lei, Yang Qi, Pei Anqi, Tong Xiaoxin, Chung Yiu-Cho, Liu Xin. A fast screening protocol for carotid plaques imaging using 3D multi-contrast MRI without contrast agent.. Magnetic resonance imaging. 2016. DOI: 10.1016/j.mri.2016.10.028.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.