Медицинская библиотека · Biochemia medica · 2020

Case report of a phantom pheochromocytoma.

Joyce Caroline M, Melvin Audrey, O'Shea Paula M, Costelloe Seán J, O'Halloran Domhnall J

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

Plasma free metanephrines or urinary fractionated metanephrines are the biochemical tests of choice for the diagnosis of pheochromocytoma as they have greater sensitivity and specificity than catecholamines for pheochromocytoma detection. This case highlights the preanalytical factors which can influence metanephrine measurement and cause a false positive result. It describes a patient with a high pre-test probability of pheochromocytoma due to hypertension and a past medical history of adrenalectomy for a purported pheochromocytoma in her home country. When biochemical screening revealed grossly elevated urine normetanephrine in the presence of a previously identified right adrenal lesion, there was high clinical suspicion of a pheochromocytoma. However, functional imaging did not support this view which prompted additional testing with plasma metanephrines. Results for plasma and urine metanephrines were discordant and preanalytical drug interference was suspected. Patient medications were reviewed and sulfasalazine, an anti-inflammatory drug was identified as the most likely analytical interferent. Urinary fractionated metanephrines were re-analysed using liquid chromatography tandem mass spectrometry (LC-MS/MS) and all metanephrines were within their reference intervals. This case illustrates how method-specific analytical drug interference prompted unnecessary expensive imaging, heightened patient anxiety and resulted in lengthy investigations for what turned out to be a phantom pheochromocytoma.

Для цитирования: Joyce Caroline M, Melvin Audrey, O'Shea Paula M, Costelloe Seán J, O'Halloran Domhnall J. Case report of a phantom pheochromocytoma.. Biochemia medica. 2020. DOI: 10.11613/bm.2020.021003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.