MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2011/861865

Медицинская библиотека · Obstetrics and gynecology international · 2011

Antenatal ultrasonographic anteroposterior renal pelvis diameter measurement: is it a reliable way of defining fetal hydronephrosis?

Pereira Alamanda Kfoury, Reis Zilma Silveira Nogueira, Bouzada Maria Cândida Ferrarez, de Oliveira Eduardo Araújo, Osanan Gabriel, Cabral Antônio Carlos Vieira

СтатьяПеревод пока не подготовлен

Аннотация

Purpose. It was to quantify the intraobserver and interobserver variability of the sonographic measurements of renal pelvis and classify hydronephrosis severity. Methods. Two ultrasonographers evaluated 17 fetuses from 23 to 39 weeks of gestation. Renal pelvis APD were taken in 50 renal units. For intraobserver error, one of them performed three sequential measurements. The mean and standard deviation from the absolute and percentage differences between measurements were calculated. Bland-Altman plots were used to visually assess the relationship between the precision of repeated measurements. Hydronephrosis was classified as mild (5.0 to 9.9 mm), moderate (10.0 to 14.9 mm), or severe (≥15.0 mm). Interrater agreement were obtained using the Kappa index. Results. Absolute intraobserver variation in APD measurements was 5.2 ± 3.5%. Interobserver variation of ultrasonographers was 9.3 ± 9.7%. Neither intraobserver or interobserver error increased with increasing APD size. The overall percentage of agreement with the antenatal hydronephrosis diagnosis was 64%. Cohen's Kappa to hydronephrosis severity was 0.51 (95% CI, 0.33 to 0.69). Conclusion. Inter and intraobserver APD measurement errors were low in these group, but the agreement to hydronephrosis diagnosis and classification was fair. We suggest that standard and serial APD measurement can better define and evaluate fetal hydronephrosis.

Для цитирования: Pereira Alamanda Kfoury, Reis Zilma Silveira Nogueira, Bouzada Maria Cândida Ferrarez, de Oliveira Eduardo Araújo, Osanan Gabriel, Cabral Antônio Carlos Vieira. Antenatal ultrasonographic anteroposterior renal pelvis diameter measurement: is it a reliable way of defining fetal hydronephrosis?. Obstetrics and gynecology international. 2011. DOI: 10.1155/2011/861865.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.