Kidney lower pole pelvicaliceal anatomy: comparative analysis between intravenous urogram and three-dimensional helical computed tomography.

Клиническое исследованиеСравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Rachid Filho Daibes, Favorito Luciano A, Costa Waldemar S, Sampaio Francisco J B

Аннотация

OBJECTIVE: The aim of our study was to evaluate if there is any advantage of three-dimensional helical computed tomography (3D-HCT) over intravenous urogram (IVU) in the morphometric and morphological analysis of lower pole spatial anatomy of the kidney.

PATIENTS AND METHODS: We analyzed 52 renal collecting systems in 30 patients, ranging in age from 23 to 80 years. The study compared the following features: (1) the angle formed between the lower infundibulum and the renal pelvis (i.e., lower infundibulum-pelvic angle [IPA]), (2) the lower infundibulum diameter (ID), and (3) the spatial distribution and number of lower pole calices (i.e., caliceal distribution [CD]). The study started with the 3D-HCT images obtained for posterior reconstruction and analysis. Afterward, we obtained anteroposterior and oblique IVU images.

RESULTS: For IPA (in degrees) we found a mean +/- standard deviation (SD) value of 75.79 +/- 15.3 with 3D-HCT and 77.4 +/- 17.17 with IVU, which were not statistically significant. For ID (in mm) we found a mean +/- SD value of 7.5 +/- 2.92 with 3D-HCT and 8.15 +/- 3.27 with IVU. For CD we found a mean +/- SD value of 2.37 +/- 0.75 calices with 3D-HCT and 2.43 +/- 0.67 calices with IVU. On analyzing the difference between 3D-HCT and IVU, we found a mean +/- SD value of 0.06 +/- 0.51, and we verified that 74.5% of the examinations compared did not present statistically significant difference, with a Wilcoxon p-value of 0.405.

CONCLUSION: Although 3D-HCT is more precise to study calculus location, tumors, and vessels, IVU was also demonstrated to be as precise as 3D-HCT for studying the lower pole spatial anatomy. We did not observe any statistically significant difference in the measurements of IPA, ID, and CD obtained using 3D-HCT when compared with those obtained using IVU. Therefore, 3D-HCT does not present any advantage over IVU in the evaluation of lower pole caliceal anatomy.