Statistically quantified measurement of an Alzheimer's marker by surface-enhanced Raman scattering.

Buividas Ričardas, Dzingelevičius Nerijus, Kubiliūtė Reda, Stoddart Paul R, Khanh Truong Vi, Ivanova Elena P, Juodkazis Saulius

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Fibrillar forms of the Amyloid-β (Aβ) protein have been implicated in the early stages of Alzheimer's disease (AD), however there are no standardised assays for soluble Aβ oligomer biomarkers that provide the best indication of the disease progression [1,2]. As a step towards a fast and label-free method for testing different AD biomarkers, we have combined laser nano-textured substrates with a SERS mapping technique and validated it using soluble Aβ-40 oligomers [3-5]. The nano-textured SERS substrates provide fast (&5 min), label-free spectra associated with soluble Aβ-40 oligomers down to a concentration of 10 nM. Statistical analysis of the spectral intensities mapped over the substrate surface shows a quantitative correlation with the oligomer concentration. Schematics of experiments: SERS mapping of Aβ-40 (left figure: measured SERS intensity overlayed with an SEM image of ripples) was carried out on the laser nano-textured (ripple) surface of sapphire and statistical analysis of the SERS intensity was carried out for qualitative (a high SERS intensity at low probability) and quantitative (a moderate SERS intenisty at the highest probability) measures. Quantitative statistical analysis of SERS mapping data can be performed off line for cross correlations with other known SERS signatures.

Для цитирования: Buividas Ričardas, Dzingelevičius Nerijus, Kubiliūtė Reda, Stoddart Paul R, Khanh Truong Vi, Ivanova Elena P, Juodkazis Saulius. Statistically quantified measurement of an Alzheimer's marker by surface-enhanced Raman scattering.. Journal of biophotonics. 2014. DOI: 10.1002/jbio.201400017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.