MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1089/dia.2019.0231

Медицинская библиотека · Diabetes technology & therapeutics · 2019

Greater Suppression of Glucagon, Lipolysis, and Ketogenesis with Insulin Glargine U300 as Compared with Glargine U100 in Type 1 Diabetes Mellitus.

Lucidi Paola, Porcellati Francesca, Cioli Patrizia, Candeloro Paola, Marinelli Andreoli Anna, Bolli Geremia B, Fanelli Carmine G

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The aim of this study was to establish the effects of clinical doses of Gla-300 versus Gla-100 on suppression of glucagon, lipolysis, and ketogenesis in type 1 diabetes mellitus (T1DM). Eighteen persons with T1DM (age 40 ± 12 years, diabetes duration 26 ± 12 years, body mass index 23.4 ± 2 kg/m2, A1C 7.19% ± 0.52% [55 ± 6 mmol/mol]) were studied after 3 months of titration with Gla-300 and Gla-100 (randomized, crossover design) with a 24-h euglycemic clamp (s.c. injection of individual insulin daily doses used by subjects for previous 2 weeks, Gla-300 0.35 ± 0.08 and Gla-100 0.28 ± 0.07 U/kg). Gla-300 resulted in (1) less increase in insulin concentration for 0-12 h, but greater insulin concentration in 12-24 h (no differences for 24 h); (2) greater glucagon suppression; (3) greater prehepatic insulin-to-glucagon molar ratio, primarily in 12-24 h (ratio 1.78, 90% confidence intervals [CIs] 1.5-2.1); and (4) lower 24-h free fatty acid (0.81; 90% CI 0.73-0.89), glycerol (0.78; 90% CI 0.65-0.94), and β-hydroxybutyrate (0.72; 90% CI 0.58-0.90). Over the 24 h postinjection, as compared with Gla-100, clinical doses of Gla-300 exhibit greater suppressive effects on glucagon, lipolysis, and ketogenesis, whereas the effects on glucose metabolism are equivalent.

Для цитирования: Lucidi Paola, Porcellati Francesca, Cioli Patrizia, Candeloro Paola, Marinelli Andreoli Anna, Bolli Geremia B, Fanelli Carmine G. Greater Suppression of Glucagon, Lipolysis, and Ketogenesis with Insulin Glargine U300 as Compared with Glargine U100 in Type 1 Diabetes Mellitus.. Diabetes technology & therapeutics. 2019. DOI: 10.1089/dia.2019.0231.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.