MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/adhm.202402148

Медицинская библиотека · Advanced healthcare materials · 2025

Kirigami-Inspired Breathable Smart Contact Lens for Wireless Monitoring of Corneal Hypoxia and Microenvironment.

Zhu Jiaxue, Yang Ling, Yang Qing, Huang Yin, Li Yuhang, He Yueqing, Yang Xuxu, Yang Zhiyan, Jiao Yonghong, Wei Wenbin, Chen Yihao, Feng Xue

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Severe corneal dysfunctions caused by corneal hypoxia and microenvironmental imbalance threaten hundreds of millions of people's eye health, leading to neovascularization, keratitis, and even vision loss, particularly among contact lens wearers. However, there are no accessible digital tools for wearable and continuous monitoring of corneal oxygen and microenvironment status. Here, a kirigami-inspired breathable smart contact lens for wireless monitoring of corneal hypoxia and microenvironment is presented. The ultrathin (55 µm) and flexible sensing device enables digitalized, in situ and precise monitoring of key eye health indicators: dissolved oxygen, humidity, and temperature (R2 > 0.98). The flexible circuit, designed and processed using evolutionary kirigami structures and thermoforming, efficiently conforms to the soft curved surfaces with minimized contour dimensions and residual stress. Silicone/hydrogel hybrid layers encapsulate the electronics, achieving high oxygen permeability (380.26 Barrers), sufficient water content (>80%), and excellent biocompatibility/heat safety. In vivo animal experiments in beagle eyes demonstrate the lens's capability for accurate, wireless corneal monitoring under controlled conditions.

Для цитирования: Zhu Jiaxue, Yang Ling, Yang Qing, Huang Yin, Li Yuhang, He Yueqing, Yang Xuxu, Yang Zhiyan, Jiao Yonghong, Wei Wenbin, Chen Yihao, Feng Xue. Kirigami-Inspired Breathable Smart Contact Lens for Wireless Monitoring of Corneal Hypoxia and Microenvironment.. Advanced healthcare materials. 2025. DOI: 10.1002/adhm.202402148.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.