BACKGROUND

Data on market-available two-piece zirconia (ZrO₂) dental implants are limited. Therefore, the aim of this retrospective study was to evaluate the clinical performance of a commercially available ZrO₂ implant system over a 24-month period.

MATERIALS AND

METHODS

In a single private dental office, 35 patients received 63 two-piece ZrO₂ implants for the support of single crowns (SC), fixed dental prostheses (FDP), and overdentures between September 2017 and October 2021. To ensure cohort homogeneity, 31 patients, which received 44 implants to support SCs, were selected for statistical analysis. An anonymized database was used to examine survival and complication rates, marginal bone loss (MBL), and soft tissue parameters. Patients were followed within a defined recall period of at least two years. Descriptive statistics (95% CI) were calculated for MBL, with paired t-tests and one-way ANOVA for comparisons. Associations and clinical parameters were analyzed using Chi-square/Fisher's exact, paired t-test, and Wilcoxon tests (p ≤ 0.05).

RESULTS

During the observation period, no implant losses or implant fractures occurred. The mean MBL was 0.24 ± 0.58 mm at 6 months, 0.18 ± 0.62 mm at 12 months, and 0.20 ± 0.66 mm at 24 months. These values were statistically within the range of random variation. MBL differed between the maxilla and mandible, but not significantly. Probing depths increased significantly over time but did not exceed 2.78 ± 0.26 mm. Bleeding on probing mean values showed a continuous decrease from 9.1 ± 13.7% at baseline to 1.1 ± 4.3% after 24 months, with significant differences between baseline and 24 months, as well from 6 to 24 months (p = 0.002 and p = 0.003 respectively).

CONCLUSION

Over 24 months, two-piece ZrO₂ implants exhibited a 100% survival rate with no observed fractures. MBL was reduced, especially in augmented sites. The presented data support the short-term suitability of this implant system for single-unit restorations.

CLINICAL TRIAL NUMBER: Not applicable.

Для цитирования: Mehnert Thomas, Noack Michael, Simon Philip, Beuer Florian, Pieralli Stefano. Clinical outcomes of a two-piece zirconia dental implant system.. International journal of implant dentistry. 2026. DOI: 10.1186/s40729-026-00717-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.