MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/diagnostics16030420

Медицинская библиотека · Diagnostics (Basel, Switzerland) · 2026

BanglaOCT2025: A Population-Specific Fovea-Centric OCT Dataset with Self-Supervised Volumetric Restoration Using Flip-Flop Swin Transformers.

Bepery Chinmay, Rahaman G M Atiqur, Debnath Rameswar, Saha Sajib, Islam Md Shafiqul, Abir Md Emranul Islam, Sarker Sanjay Kumar

СтатьяПеревод пока не подготовлен

Аннотация

Background

Age-related macular degeneration (AMD) is a major cause of vision loss, yet publicly available Optical Coherence Tomography (OCT) datasets lack demographic diversity, particularly from South Asian populations. Existing datasets largely represent Western cohorts, limiting AI generalizability. Moreover, raw OCT volumes contain redundant spatial information and speckle noise, hindering efficient analysis.

Methods

We introduce BanglaOCT2025, a retrospective dataset collected from the National Institute of Ophthalmology and Hospital (NIOH), Bangladesh, using Nidek RS-330 Duo 2 and RS-3000 Advance systems. We propose a novel preprocessing pipeline comprising two stages: (1) A constraint-based centroid minimization algorithm automatically localizes the foveal center and extracts a fixed 33-slice macular sub-volume, robust to retinal tilt and acquisition variability; and (2) A self-supervised volumetric denoising module based on a Flip-Flop Swin Transformer (FFSwin) backbone suppresses speckle noise without requiring paired clean reference data.

Results

The dataset comprises 1585 OCT volumes (202,880 B-scans), including 857 expert-annotated cases (54 DryAMD, 61 WetAMD, and 742 NonAMD). Denoising quality was evaluated using reference-free volumetric metrics, paired statistical analysis, and blinded clinical review by a retinal specialist, confirming preservation of pathological biomarkers and absence of hallucination. Under a controlled paired evaluation using the same classifier with frozen weights, downstream AMD classification accuracy improved from 69.08% to 99.88%, interpreted as an upper-bound estimate of diagnostic signal recoverability rather than independent generalization.

Conclusions

BanglaOCT2025 is the first clinically validated OCT dataset representing the Bengali population and establishes a reproducible fovea-centric volumetric preprocessing and restoration framework for AMD analysis, with future validation across independent and multi-centre test cohorts.

Для цитирования: Bepery Chinmay, Rahaman G M Atiqur, Debnath Rameswar, Saha Sajib, Islam Md Shafiqul, Abir Md Emranul Islam, Sarker Sanjay Kumar. BanglaOCT2025: A Population-Specific Fovea-Centric OCT Dataset with Self-Supervised Volumetric Restoration Using Flip-Flop Swin Transformers.. Diagnostics (Basel, Switzerland). 2026. DOI: 10.3390/diagnostics16030420.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.