Hale Michael J, Zellner Eric M, Naiman Jaron H, Kraus Karl H
Аннотация
OBJECTIVE: To determine the influence of suture patterns on resistance to gap formation after tendon plating STUDY DESIGN: Ex vivo study SAMPLE POPULATION: Suspensory ligament and superficial and deep digital flexor tendons harvested from 16 neonatal cadaver foal limbs.
METHODS: Each tendon/ligament from a given limb was randomly assigned to one of three treatment groups consisting of a 7-hole veterinary cuttable plate fixed with alternating simple interrupted, figure-8, or hybrid suture patterns. The constructs were distracted at a rate of 1.0 mm/s to failure, as determined by the formation of a 1 mm gap for initial failure and a 3 mm gap for ultimate failure. The mode of failure was also recorded.
RESULTS: Constructs prepared with hybrid and figure-8 patterns sustained over 2× higher (p < .01) forces before gap formation compared to those prepared with a simple interrupted pattern. No difference was identified between tendons whose plate was secured with hybrid or figure-8 suture patterns. Mode of failure between groups did not differ.
CONCLUSION: The figure-8 and hybrid patterns described herein improved the resistance to gap formation of plated tendons compared to an alternating simple interrupted pattern described previously.
CLINICAL SIGNIFICANCE: Figure-8 and hybrid patterns should be considered over simple interrupted patterns to improve resistance to gap formation in horses undergoing tendon plating.
METHODS: Each tendon/ligament from a given limb was randomly assigned to one of three treatment groups consisting of a 7-hole veterinary cuttable plate fixed with alternating simple interrupted, figure-8, or hybrid suture patterns. The constructs were distracted at a rate of 1.0 mm/s to failure, as determined by the formation of a 1 mm gap for initial failure and a 3 mm gap for ultimate failure. The mode of failure was also recorded.
RESULTS: Constructs prepared with hybrid and figure-8 patterns sustained over 2× higher (p < .01) forces before gap formation compared to those prepared with a simple interrupted pattern. No difference was identified between tendons whose plate was secured with hybrid or figure-8 suture patterns. Mode of failure between groups did not differ.
CONCLUSION: The figure-8 and hybrid patterns described herein improved the resistance to gap formation of plated tendons compared to an alternating simple interrupted pattern described previously.
CLINICAL SIGNIFICANCE: Figure-8 and hybrid patterns should be considered over simple interrupted patterns to improve resistance to gap formation in horses undergoing tendon plating.