MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10792-024-03218-2

Медицинская библиотека · International ophthalmology · 2024

Coefficient of spatial variance of choroidal thickness on swept-source optical coherence tomography in healthy eyes.

Jiang Zehua, Lin Tian, Lin Aidi, Lin Jianwei, Chen Shirong, Zhou Lingling, Chen Haoyu

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: This study aims to introduce the coefficient of spatial variance of choroidal thickness to describe the choroidal variation and investigate its associated factors in healthy eyes.

METHODS

This retrospective cross-sectional study included 1031 eyes from 1031 subjects who received a swept-source optical coherence tomography examination. The mean choroidal thickness in the macular 6 × 6 mm region and 900 subregions of 0.2 × 0.2 mm were computed using the embedded algorithm. Before analysis, potential segmentation and magnification errors were corrected. The coefficient of spatial variance was defined as the standard deviation divided by the mean (multiplied by 100%) of the choroidal thicknesses across 900 grids. Potential factors associated with the coefficient of spatial variance were assessed using multiple linear regression.

RESULTS

The mean choroidal thickness of the entire 6 × 6 mm macular region was 204.50 ± 72.88 μm. The mean coefficient of spatial variance was 26.58 ± 8.24%, ranging from 11.00 to 61.58%. Statistical analysis revealed that the means choroidal thickness (β = - 0.08, R2 = 0.42, p < 0.001) and anterior chamber depth (β = - 2.39, R2 = 0.05, p = 0.06) were associated with the coefficient of spatial variance.

CONCLUSION

Our study first incorporated the coefficient of spatial variance to represent the spatial variation of the choroidal thickness and observed that the greater thinning of the choroid is correlated with a more pronounced spatial variation.

Для цитирования: Jiang Zehua, Lin Tian, Lin Aidi, Lin Jianwei, Chen Shirong, Zhou Lingling, Chen Haoyu. Coefficient of spatial variance of choroidal thickness on swept-source optical coherence tomography in healthy eyes.. International ophthalmology. 2024. DOI: 10.1007/s10792-024-03218-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.