MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-020-07342-2

Медицинская библиотека · European radiology · 2020

Diagnostic efficiency of 68Ga-DOTANOC PET/CT in patients with suspected tumour-induced osteomalacia.

He Qiao, Zhang Bing, Zhang Linqi, Chen Zhifeng, Shi Xinchong, Yi Chang, Wang Xiaoyan, Zhang Xiangsong

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Currently, the main challenge in tumour-induced osteomalacia (TIO) is the difficulty in locating culprit tumours for definitive diagnosis and surgical therapy. Herein, we retrospectively evaluate the efficiency of 68Ga-DOTANOC PET/CT in the localisation and diagnosis of TIO, and compared with 18F-FDG.

METHODS

Twenty-four consecutive patients with hypophosphataemic osteomalacia (HO) and suspicion of TIO who were referred to our centre for 68Ga-DOTANOC PET/CT scanning were retrospectively reviewed. The images were evaluated qualitatively as well as semi-quantitatively, and imaging results were compared with the final diagnoses.

RESULTS

Among the total of 21 patients who were included in the final analyses, 17 were diagnosed with TIO, while four were proven to have other causes of HO. 68Ga-DOTANOC PET/CT produced positive results in 16 of the 17 patients with TIO, representing a sensitivity of 94.1%. Moreover, the 68Ga-DOTANOC PET/CT results were negative in 3 of the 4 patients without TIO, representing a specificity of 75.0%. The overall accuracy of 68Ga-DOTANOC PET/CT in locating the tumours responsible for TIO is 90.5%. In particular, 68Ga-DOTANOC PET/CT detected the culprit tumours in 4 out of 10 patients with negative results on previous 18F-FDG PET/CT and showed a significantly higher T/M ratio of tumours than 18F-FDG PET/CT in the same patients (n = 10; 4.76 ± 3.08 vs 1.95 ± 1.33, p < 0.05).

CONCLUSIONS

68Ga-DOTANOC PET/CT is an accurate imaging modality in the localisation of tumours for TIO. It is superior to 18F-FDG PET/CT and may be useful in the differential diagnosis of HO.

KEY POINTS: • TIO should be considered a possible cause for patients diagnosed with HO, which usually needs to be differentiated from other aetiologies. • 68Ga-DOTANOC PET/CT is an accurate imaging modality in locating culprit tumours for TIO, superior to 18F-FDG PET/CT.

Для цитирования: He Qiao, Zhang Bing, Zhang Linqi, Chen Zhifeng, Shi Xinchong, Yi Chang, Wang Xiaoyan, Zhang Xiangsong. Diagnostic efficiency of 68Ga-DOTANOC PET/CT in patients with suspected tumour-induced osteomalacia.. European radiology. 2020. DOI: 10.1007/s00330-020-07342-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.