MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.talanta.2026.130384

Медицинская библиотека · Talanta · 2026

Sensitive anti-interference trace methane detection system based on novel hollow-core anti-resonant fiber combined with wavelength modulation spectroscopy.

Zhang Wenke, Zhang Yungang, Li Juncheng, Li Changyin, Dong Haiyang, Han Boya, Zhao Xingtao

СтатьяПеревод пока не подготовлен

Аннотация

Optical spectroscopic detection of methane underpins high-precision greenhouse gas quantification, source tracing and climate mitigation research. Nevertheless, traditional optical gas detection systems rely on free-space optics and discrete gas cells, suffering from large volume, complex alignment, and poor anti-interference capability. We fabricated a large-aperture five-tube double-nested hollow-core anti-resonant fiber (HC-ARF) and constructed a gas cell system with integrated gas filling and free-space optical coupling functions. The designed HC-ARF serves as both an optical waveguide and a miniature gas cell, significantly reducing optical loss and system footprint while greatly enhancing gas-light interaction efficiency. We developed an all-fiber system combined with wavelength modulation spectroscopy (WMS). Using a 1654 nm Distributed Feedback Laser (DFB) laser and optimized modulation parameters, we acquired second harmonic (2f) spectra for methane concentration measurement.The system achieves an ultra-low optimum steady-state limit of detection (LOD) of 0.02 ppm with an effective optical path length of 5 m and an averaging time of 40.2 s. The 90% rise response time was only 60 s at 1.8 bar, and the response performance can be further improved by adjusting the gas pressure. Two-day continuous atmospheric methane monitoring verified the sensor's excellent stability and environmental adaptability. Benefiting from its compact structure, high sensitivity and excellent immunity to external interference, this all-fiber sensor holds broad application prospects in atmospheric monitoring and industrial leakage early warning.

Для цитирования: Zhang Wenke, Zhang Yungang, Li Juncheng, Li Changyin, Dong Haiyang, Han Boya, Zhao Xingtao. Sensitive anti-interference trace methane detection system based on novel hollow-core anti-resonant fiber combined with wavelength modulation spectroscopy.. Talanta. 2026. DOI: 10.1016/j.talanta.2026.130384.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.