MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20150122-08

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2015

Study of the force dynamics at the capsular interface related to ciliary body stimulation in a primate model.

Alió Jorge L, Ben-Nun Joshua

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To study the mechanical dynamics between the zonuli-capsular complex and an accommodating intraocular lens mechanics simulator using pharmacological stimulation of the ciliary body in a primate eye.

METHODS

Following phacoemulsification removal of the lens, force/movement gauges simulating the accommodating intraocular lens mechanics were implanted in 8 primate eyes (4 positioned in-the-bag and 4 on-the-bag). The gauge readings were taken under full effect of pilocarpine 4% or atropine 1% starting 6 weeks after surgery and following 3-month intervals for 30 months.

RESULTS

An average movement of 390 µm for on-the-bag gauges and 145 µm for in-the-bag gauges was documented at 3 months postoperatively. The mechanical compliance of in-the-bag gauges rapidly deteriorated with capsular fibrosis developing inside the gauge and the capsular bag shrinking around it. On-the-bag gauges remained functional but the initial compliance was compromised over time by the pressure build up caused by the fibrotic capsular bag.

CONCLUSIONS

Following phacoemulsification, capsular fibrosis causes disappearance of the mechanical forces detected by an in-the-bag gauge. An on-the-bag gauge detects active forces at the sulcus lasting at least 5 years, although the contracting capsule pressure compromises its compliance. These findings have important implications for future accommodating intraocular lens designs.

Для цитирования: Alió Jorge L, Ben-Nun Joshua. Study of the force dynamics at the capsular interface related to ciliary body stimulation in a primate model.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2015. DOI: 10.3928/1081597x-20150122-08.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.