MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ejcts/ezv038

Медицинская библиотека · European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2015

A comparison of aortic valve replacement via an anterior right minithoracotomy with standard sternotomy: a propensity score analysis of 492 patients.

Bowdish Michael E, Hui Dawn S, Cleveland John D, Mack Wendy J, Sinha Raina, Ranjan Rupesh, Cohen Robbin G, Baker Craig J, Cunningham Mark J, Barr Mark L, Starnes Vaughn A

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

Right anterior minithoracotomy with central arterial cannulation is our preferred technique of minimally invasive aortic valve replacement (AVR). We compared perioperative outcomes with this technique to those via sternotomy.

METHODS

Between March 1999 and December 2013, 492 patients underwent isolated AVR via either sternotomy (SAVR, n = 198) or minimally invasive right anterior thoracotomy (MIAVR, n = 294) in our institution. Univariate comparisons between groups were made to evaluate overall outcomes and adverse events. To control treatment selection bias, propensity scores were constructed from core patient characteristics. A propensity score-stratified analysis of outcome and adverse events was then performed.

RESULTS

Overall mortality was 2.5 and 1.0% in the SAVR and MIAVR groups, respectively. Hospital and ICU stays were shorter, there was less intraoperative blood product usage, and fewer wound infections in the MIAVR group. There were no differences in other adverse events, including strokes. The composite end-point of alive and adverse event-free was significantly more common in the MIAVR group (83 vs 74%, P = 0.002). After adjusting for the propensity score, hospital and ICU stays remained shorter and intraoperative blood product usage remained less in the MIAVR group. There was no difference in mortality, stroke or other adverse events between groups.

CONCLUSION

Minimally invasive AVR via an anterior right thoracotomy with predominately central cannulation can be performed with morbidity and mortality similar to that of a sternotomy approach. There appear to be advantages to this minimally invasive approach when compared with sternotomy in terms of less intraoperative blood product usage, lower wound infection rates and decreased hospital stays. If mortality and the occurrence of adverse events are taken together, MIAVR may be associated with better outcomes. As minimally invasive AVR becomes more common, further long-term follow-up is needed and a prospective multicentre randomized trial would be warranted.

Для цитирования: Bowdish Michael E, Hui Dawn S, Cleveland John D, Mack Wendy J, Sinha Raina, Ranjan Rupesh, Cohen Robbin G, Baker Craig J, Cunningham Mark J, Barr Mark L, Starnes Vaughn A. A comparison of aortic valve replacement via an anterior right minithoracotomy with standard sternotomy: a propensity score analysis of 492 patients.. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 2015. DOI: 10.1093/ejcts/ezv038.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.