JACC. Heart failure · 2014

Reduced risk for inappropriate implantable cardioverter-defibrillator shocks with dual-chamber therapy compared with single-chamber therapy: results of the randomized OPTION study.

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kolb Christof, Sturmer Marcio, Sick Peter, Reif Sebastian, Davy Jean Marc, Molon Giulio, Schwab Jörg Otto, Mantovani Giuseppe, Dan Dan, Lennerz Carsten, Borri-Brunetto Alberto, Babuty Dominique

Аннотация

OBJECTIVES: The OPTION (Optimal Anti-Tachycardia Therapy in Implantable Cardioverter-Defibrillator Patients Without Pacing Indications) trial sought to compare long-term rates of inappropriate shocks, mortality, and morbidity between dual-chamber and single-chamber settings in implantable cardioverter-defibrillators (ICDs) patients.

BACKGROUND: The use of dual-chamber ICDs potentially allows better discrimination of supraventricular arrhythmias and thereby reduces inappropriate shocks. However, it may lead to detrimental ventricular pacing.

METHODS: This prospective multicenter, single-blinded trial enrolled 462 patients with de novo primary or secondary prevention indications for ICD placement and with left ventricular ejection fractions ≤40% despite optimal tolerated pharmacotherapy. All patients received atrial leads and dual-chamber defibrillators that were randomized to be programmed either with dual-chamber or single-chamber settings. In the dual-chamber setting arm, the PARAD+ algorithm, which differentiates supraventricular from ventricular arrhythmias, and SafeR mode, to minimize ventricular pacing, were activated. In the single-chamber setting arm, the acceleration, stability, and long cycle search discrimination criteria were activated, and pacing was set to VVI 40 beats/min. Ventricular tachycardia detection was required at rates between 170 and 200 beats/min, and ventricular fibrillation detection was activated above 200 beats/min.

RESULTS: During a follow-up period of 27 months, the time to the first inappropriate shock was significantly longer in the dual-chamber setting arm (p = 0.012, log-rank test), and 4.3% of patients in the dual-chamber setting group compared with 10.3% in the single-chamber setting group experienced inappropriate shocks (p = 0.015). Rates of all-cause death or cardiovascular hospitalization were 20% for the dual-chamber setting group and 22.4% for the single-chamber setting group and satisfied the pre-defined margin for equivalence (p < 0.001).

CONCLUSIONS: Therapy with dual-chamber settings for ICD discrimination combined with algorithms for minimizing ventricular pacing was associated with reduced risk for inappropriate shock compared with single-chamber settings, without increases in mortality and morbidity. (Optimal Anti-Tachycardia Therapy in Implantable Cardioverter-Defibrillator [ICD] Patients Without Pacing Indications [OPTION]; NCT00729703).