MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.25621

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2014

Svelte integrated delivery system performance examined through diagnostic catheter delivery: the SPEED registry.

Khattab Ahmed A, Nijhoff Freek, Schofer Joachim, Berland Jacques, Meier Bernhard, Nietlispach Fabian, Agostoni Pierfrancesco, Brucks Steffen, Stella Pieter

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

AIMS: The multi-center SPEED registry evaluated the procedural success and in-hospital clinical outcomes of direct stenting with the Svelte 'all-in-one' coronary stent Integrated Delivery System (IDS) through diagnostic catheters to identify the clinical indications for which this approach is appropriately suited.

METHODS &

RESULTS

Forty-eight (48) patients with 54 lesions of lengths ≤20 mm and RVD 2.5-3.5 mm were targeted for direct stenting through diagnostic catheters (4-6F) via radial or femoral approach. Procedural characteristics early in an investigator's experience (28 lesions) were compared with outcomes following experience (26 lesions). Procedure, device and strategy success were realized in 54 (100%), 50 (93%) and 46 (85%) lesions, respectively, with strategy success significantly related to RVD (P = 0.05), lesion location (P = 0.01), and diagnostic catheter size (P = 0.05). Significant improvement in crossing and intervention time and trends toward improvement in device and strategy success, reductions in procedure and radiation time and contrast use were observed.

CONCLUSIONS

Direct stenting through diagnostic catheters via radial or femoral approach using the Svelte IDS is feasible and associated with good in-hospital outcomes. This approach offers the attractive option of assessing lesions via diagnostic catheter and, depending upon vessel anatomy and lesion morphology, continuing with ad-hoc interventional treatment using the same diagnostic catheter. Improvements in strategy success and procedural efficiencies, based on operator experience, facilitate catheter downsizing and reduce intervention time, ancillary product use and overall procedure costs. © 2014 Wiley Periodicals, Inc.

Для цитирования: Khattab Ahmed A, Nijhoff Freek, Schofer Joachim, Berland Jacques, Meier Bernhard, Nietlispach Fabian, Agostoni Pierfrancesco, Brucks Steffen, Stella Pieter. Svelte integrated delivery system performance examined through diagnostic catheter delivery: the SPEED registry.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2014. DOI: 10.1002/ccd.25621.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.