MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2214/ajr.11.6981

Медицинская библиотека · AJR. American journal of roentgenology · 2012

3-T high-resolution MR neurography of sciatic neuropathy.

Chhabra Avneesh, Chalian Majid, Soldatos Theodoros, Andreisek Gustav, Faridian-Aragh Neda, Williams Eric, Belzberg Allan J, Carrino John A

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The sciatic nerve may normally exhibit mild T2 hyperintensity in MR neurography (MRN) images, rendering assessment of sciatic neuropathy difficult. The purpose of this case-control study was to evaluate whether a quantitative and qualitative analysis of the sciatic nerves and regional skeletal muscles increases the accuracy of MRN in detecting sciatic neuropathy.

MATERIALS AND

METHODS

We retrospectively reviewed the MRN studies of the pelvis and thighs of 34 subjects (12 men and 22 women; mean [± SD] age, 50 ± 15 years), of which 17 had a final diagnosis of sciatic neuropathy according to electrodiagnostic or surgical confirmation, and 17 had no evidence of sciatic neuropathy and served as control subjects. On each side, the sciatic nerves were evaluated for signal intensity (SI), size, course, and fascicular shape, whereas the regional skeletal muscles were evaluated for edema, fatty replacement, and atrophy. In addition, the nerve-to-vessel SI ratio was registered for each side at the same time and 8 months later.

RESULTS

The sciatic nerves of the abnormal sides exhibited higher nerve-to-vessel SI ratios and higher incidences of T2 hyperintensity, enlargement, and abnormal fascicular shape compared to the nerves of the normal sides. The regional muscles of the abnormal sides demonstrated a higher grade of fatty infiltration and higher frequencies of edema and atrophy. A cutoff value of nerve-to-vessel SI ratio of 0.89 exhibited high sensitivity and specificity in predicting sciatic neuropathy. Calculation of the nerve-to-vessel SI ratio demonstrated excellent inter- and intraobserver reliability.

CONCLUSION

Both qualitative and quantitative criteria should be used to suggest the MRN diagnosis of sciatic neuropathy.

Для цитирования: Chhabra Avneesh, Chalian Majid, Soldatos Theodoros, Andreisek Gustav, Faridian-Aragh Neda, Williams Eric, Belzberg Allan J, Carrino John A. 3-T high-resolution MR neurography of sciatic neuropathy.. AJR. American journal of roentgenology. 2012. DOI: 10.2214/ajr.11.6981.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.