MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/trf.15837

Медицинская библиотека · Transfusion · 2020

Clinical data for intravenous iron - debunking the hype around hypersensitivity.

Achebe Maureen, DeLoughery Thomas G

СтатьяПоддержка исследования: вне правительства СШАОбзорПеревод пока не подготовлен

Аннотация

BACKGROUND

Reluctance to use intravenous (IV) iron for the treatment of iron deficiency continues due to a perceived high risk of severe hypersensitivity reactions (HSRs). Additionally, it has been hypothesized that 'dextran-derived' IV iron products (e.g., ferumoxytol [FER] and ferric derisomaltose/iron isomaltoside 1000 [FDI]) have a higher risk of severe HSRs than 'non-dextran-derived' products (e.g., ferric carboxymaltose [FCM] and iron sucrose [IS]). In the present analysis, HSR data from head-to-head randomized controlled trials (RCTs) with IV iron products were evaluated to determine if differences in safety signals are present among these IV iron formulations.

STUDY DESIGN AND

METHODS

Reported serious or moderate-to-severe HSR incidence data from five RCTs (FIRM; FERWON-NEPHRO/-IDA; PHOSPHARE-IDA04/-IDA05) were used to calculate risk differences with 95% confidence intervals (CIs) for FER, FCM, FDI, and IS. The rates and risk differences for these HSRs were compared.

RESULTS

The analysis included data for 5247 patients: FER (n = 997), FCM (n = 1117), FDI (n = 2133) and IS (n = 1000). Overall rates of serious or moderate to severe HSRs were low (0.2%-1.7%). The risk differences (95% CIs) showed small differences between the IV iron formulations: FER versus FCM, -0.1 (-0.8 to 0.6); FDI versus IS, 0.1 (-0.3 to 0.5); FDI versus FCM, -0.9 (-3.7 to 1.9).

CONCLUSION

RCT evidence confirms a low risk of serious or moderate to severe HSRs with newer IV iron formulations and no significant differences among existing commercially available products. Thus, RCT data show that the supposed classification of dextran-derived versus non-dextran-derived IV iron products has no clinical relevance.

Для цитирования: Achebe Maureen, DeLoughery Thomas G. Clinical data for intravenous iron - debunking the hype around hypersensitivity.. Transfusion. 2020. DOI: 10.1111/trf.15837.