m+Medelevator.RU
← Поиск публикаций
Cardiovascular pathology : the official journal of the Society for Cardiovascular Pathology · 2014

Myocardial hydrophilic polymer emboli following cardiac catheterization: a case report and literature review.

Клинический случайСтатьяОбзорНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Rosen Lauren E, Singh Rohit I, Mahon Brett

Аннотация

BACKGROUND: Intravascular polymer emboli have been reported in the skin, lungs, and brain following vascular procedures utilizing hydrophilic polymer coated devices. The Cook arterial introducer sheath was the first of these devices to be introduced, after which case reports followed documenting sterile inflammation at the sheath access site, characterized histologically by perivascular granulomas containing hydrophilic polymer. More recently, hydrophilic polymer emboli have been reported in the vessels of the lungs and brain in association with ischemia and infarct following vascular procedures using polymer coated devices.

METHODS: We report a case of intravascular myocardial emboli associated with acute myocardial infarction following cardiac catheterization. The patient was a 65-year-old man who received cardiac catheterization with placement of a bare metal stent following myocardial infarction. One month later, the patient presented with angina and died shortly after admission.

RESULTS: Autopsy revealed hemopericardium with rupture of the left ventricle through an aneurismal defect within the area of prior infarction. Microscopically, an area of acute infarction was present within the aneurismal defect. Numerous small and medium-sized vessels within the left ventricle were occluded by basophilic amorphous granular material with an inflammatory giant cell response.

CONCLUSION: The emboli were most frequent in the area of acute infarction, suggesting that the emboli may have resulted in ischemia leading to the patient's death. This is the third documented case of intramyocardial polymer emboli following cardiac catheterization and the first case to our knowledge to document an association between intravascular myocardial polymer emboli and acute myocardial infarction.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты