MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/cod.13767

Медицинская библиотека · Contact dermatitis · 2021

Associated positive patch test reactions to standard contact allergens: 10-year data from the Slovenian E-Surveillance System.

Dugonik Aleksandra, Dugonik Bogdan, Podgorelec Vili, Brezočnik Lucija

СтатьяПеревод в очереди

Аннотация

BACKGROUND

A considerable share of patients tested with a baseline patch test series respond with a positive reaction to more than one allergen, and some associations between synchronous positive reactions to distinct baseline patch allergens have been described in the literature.

OBJECTIVES

To evaluate the prevalence of sensitization to haptens of the European baseline series as well as the prevalence of oligosensitization and polysensitization and the most significant associated positive patch test reactions in Slovenia.

METHODS

Patch testing data collected by the Slovenian E-Surveillance System from January 2008 to December 2017 were retrospectively analysed.

RESULTS

Of a total of 15 171 patients analysed, 39.29% showed at least one positive reaction. The highest prevalences were noted for metals (nickel[II]sulfate hexahydrate: 16.33%) and fragrances (fragrance mix I: 6.70%). The correlation analysis showed the strongest correlation between mercapto mix and 2-mercaptobenzothiazole (61.2%), fragrance Mix II and hydroxyisohexyl 3-cyclohexene carboxaldehyde (50.5%), and potassium dichromate and cobalt(II) chloride hexahydrate (33.3%).

CONCLUSIONS

Sensitization prevalences to the most common haptens were described, and their strongest correlations on a national level quantified. A comparison with other European results confirms already known associations between allergens in terms of cross-reactivity.

Для цитирования: Dugonik Aleksandra, Dugonik Bogdan, Podgorelec Vili, Brezočnik Lucija. Associated positive patch test reactions to standard contact allergens: 10-year data from the Slovenian E-Surveillance System.. Contact dermatitis. 2021. DOI: 10.1111/cod.13767.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.