MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.25255

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2015

First in vivo evaluation of a flexible self-apposing left atrial appendage closure device in the canine model.

Cheng Yanping, Conditt Gerard, Yi Genghua, Tellez Armando, Corcoran Michael, Rousselle Serge, Kaluza Greg L, Granada Juan F

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Aimed to evaluate the feasibility of deployment and healing response of a novel transcatheter left atrial appendage (LAA) occlusion device in the canine model

BACKGROUND

LAA occlusion is proposed to reduce the risk of stroke in atrial fibrillation patients

METHODS

Transseptal puncture and device deployment was guided under fluoroscopy and transesophageal echocardiography (TEE) in five dogs. First, a distal cylindrical bulb occluder was released and secured to the appendage wall with hooks. Subsequently, a proximal sail was unfolded, covering the LAA ostium. Rotational angiography, TEE, and histology outcomes were assessed 30 days following implantation

RESULTS

Pre-operative TEE revealed the mean diameter of the LAA ostium to be 17.2 ± 1.6 mm with a depth of 18.5 ± 1.7 mm. The landing zone for the distal bulb was measured to be 12.8 ± 1.3 mm. The mean bulb diameter at implant was 16.8 ± 1.8 mm. Post-operative TEE showed adequate positioning and successful LAA occlusion with all implanted devices. Pericardial effusion requiring pericardiocentesis was seen in one animal following device implantation. At 30 days, TEE revealed full occlusion of all LAA ostia with the exception of a minimal peri-device leak (<3 mm) observed in one animal. No pericardial effusion or device-related thrombus formation was found at termination. Histological analysis confirmed circumferential occlusion of all appendages and complete neointimal coverage on the luminal aspect of the occluder

CONCLUSION

The percutaneous delivery of a novel self-positioning LAA occlusion device is feasible and safe in a canine model. At 30 days, all devices displayed complete healing and occlusion of the LAA without any device related adverse events.

Для цитирования: Cheng Yanping, Conditt Gerard, Yi Genghua, Tellez Armando, Corcoran Michael, Rousselle Serge, Kaluza Greg L, Granada Juan F. First in vivo evaluation of a flexible self-apposing left atrial appendage closure device in the canine model.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2015. DOI: 10.1002/ccd.25255.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.