m+Medelevator.RU
← Поиск публикаций
International journal of cardiology · 2013

Robotically assisted ablation of atrial fibrillation: a systematic review and meta-analysis.

Клинический случайСтатьяМетаанализСистематический обзорНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Shurrab Mohammed, Danon Asaf, Lashevsky Ilan, Kiss Alex, Newman David, Szili-Torok Tamas, Crystal Eugene

Аннотация

BACKGROUND: Robotic systems are becoming increasingly common in complex ablation procedures. We conducted systematic review and meta-analysis on the procedural outcomes of Magnetic Navigation System (MNS) in comparison to conventional catheter navigation for atrial fibrillation (AF) ablation.

METHODS: An electronic search was performed using multiple databases between 2002 & 2012. Outcomes were: acute and long-term success, complications, total procedure, ablation and fluoroscopic times.

RESULTS: Fifteen studies (11 nonrandomized controlled studies & 4 case series) involving 1647 adult patients were identified. In comparison between MNS and conventional groups, a tendency towards higher acute success was noted with conventional group but with similar long-term freedom from AF (95% vs. 97%, odds ratio (OR) 0.25 (95% confidence interval [CI] 0.06; 1.04, p=0.057); 73% vs. 75%, OR 0.92 (95% CI 0.69; 1.24, p=0.59), respectively). A significantly shorter fluoroscopic time was achieved with MNS (57 vs. 86 min, standardized difference in means (SDM) -0.90 (95% CI -1.68; -0.12, p=0.024)). Longer total procedure and ablation times were noted with MNS (286 vs. 228 min, SDM 0.7 (95% CI 0.28; 1.12, p=0.001); 67 vs. 47 min, SDM 0.79 (95% CI 0.18; 1.4, p=0.012), respectively). Overall complication rate was similar (2% vs. 5%, OR 0.48 (95% CI 0.18; 1.26, p=0.135)), however rate of significant pericardial complication defined either as tamponade or effusion requiring intervention/hospitalization was significantly lower in MNS (0.3% vs. 2.5%, p=0.005).

CONCLUSIONS: Our results suggest that MNS has similar rates of success and possibly superior safety outcomes when compared to conventional manual catheter ablation for AF.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты