MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/eul098

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2006

Transcatheter ablation through the cardiac veins in a patient with a biventricular device and left ventricular epicardial arrhythmias.

Mantica Massimo, De Luca Lucia, Fagundes Rafael, Tondo Claudio

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

Left ventricular outflow tract (LVOT) may be a source of repeated premature ventricular complexes (PVCs). In symptomatic patients, radiofrequency catheter ablation (RFCA) can be effective, either from endocardial or from epicardial sites. A 50-year-old patient, with dilated cardiomyopathy (DCM) and severe left ventricular (LV) dysfunction, left bundle branch block (LBBB), New York Heart Association (NYHA) class IV, received a biventricular implantable cardioverter/defibrillator (ICD) in 2002. Despite drug therapy, PVCs were frequent (21.019/24 h) including prolonged runs, prompting ICD intervention. Premature ventricular complexes showed an inferior axis morphology, with an R/S ratio in V3>1, suggesting an LVOT origin. Despite the cardiac resynchronization therapy (CRT) device, successful RFCA was performed through the anterior venous branch, with a favourable clinical outcome. To our knowledge, this is the first case describing epicardial RFCA of a PVC focus from cardiac veins in the presence of a CRT device.

Для цитирования: Mantica Massimo, De Luca Lucia, Fagundes Rafael, Tondo Claudio. Transcatheter ablation through the cardiac veins in a patient with a biventricular device and left ventricular epicardial arrhythmias.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2006. DOI: 10.1093/europace/eul098.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.