MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/cancers16061210

Медицинская библиотека · Cancers · 2024

Clinical Workflow of Cone Beam Computer Tomography-Based Daily Online Adaptive Radiotherapy with Offline Magnetic Resonance Guidance: The Modular Adaptive Radiotherapy System (MARS).

Kim Ji-Young, Tawk Bouchra, Knoll Maximilian, Hoegen-Saßmannshausen Philipp, Liermann Jakob, Huber Peter E, Lifferth Mona, Lang Clemens, Häring Peter, Gnirs Regula, Jäkel Oliver, Schlemmer Heinz-Peter, Debus Jürgen, Hörner-Rieber Juliane, Weykamp Fabian

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The Ethos (Varian Medical Systems) radiotherapy device combines semi-automated anatomy detection and plan generation for cone beam computer tomography (CBCT)-based daily online adaptive radiotherapy (oART). However, CBCT offers less soft tissue contrast than magnetic resonance imaging (MRI). This work aims to present the clinical workflow of CBCT-based oART with shuttle-based offline MR guidance.

METHODS

From February to November 2023, 31 patients underwent radiotherapy on the Ethos (Varian, Palo Alto, CA, USA) system with machine learning (ML)-supported daily oART. Moreover, patients received weekly MRI in treatment position, which was utilized for daily plan adaptation, via a shuttle-based system. Initial and adapted treatment plans were generated using the Ethos treatment planning system. Patient clinical data, fractional session times (MRI + shuttle transport + positioning, adaptation, QA, RT delivery) and plan selection were assessed for all fractions in all patients.

RESULTS

In total, 737 oART fractions were applied and 118 MRIs for offline MR guidance were acquired. Primary sites of tumors were prostate (n = 16), lung (n = 7), cervix (n = 5), bladder (n = 1) and endometrium (n = 2). The treatment was completed in all patients. The median MRI acquisition time including shuttle transport and positioning to initiation of the Ethos adaptive session was 53.6 min (IQR 46.5-63.4). The median total treatment time without MRI was 30.7 min (IQR 24.7-39.2). Separately, median adaptation, plan QA and RT times were 24.3 min (IQR 18.6-32.2), 0.4 min (IQR 0.3-1,0) and 5.3 min (IQR 4.5-6.7), respectively. The adapted plan was chosen over the scheduled plan in 97.7% of cases.

CONCLUSION

This study describes the first workflow to date of a CBCT-based oART combined with a shuttle-based offline approach for MR guidance. The oART duration times reported resemble the range shown by previous publications for first clinical experiences with the Ethos system.

Для цитирования: Kim Ji-Young, Tawk Bouchra, Knoll Maximilian, Hoegen-Saßmannshausen Philipp, Liermann Jakob, Huber Peter E, Lifferth Mona, Lang Clemens, Häring Peter, Gnirs Regula, Jäkel Oliver, Schlemmer Heinz-Peter, Debus Jürgen, Hörner-Rieber Juliane, Weykamp Fabian. Clinical Workflow of Cone Beam Computer Tomography-Based Daily Online Adaptive Radiotherapy with Offline Magnetic Resonance Guidance: The Modular Adaptive Radiotherapy System (MARS).. Cancers. 2024. DOI: 10.3390/cancers16061210.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.