Circulation. Arrhythmia and electrophysiology · 2026
Utilization and Outcomes of Permanent Pacemakers After Bicaval Heart Transplantation: A Large Institutional Experience.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Sheppard John P, Khan Abdul K, Kransdorf Evan P, Kittleson Michelle M, Kobashigawa Jon A, Ramireddy Archana, Ehdaie Ashkan, Wang Xunzhang, Shehata Michael M, Braunstein Eric D
Аннотация
BACKGROUND: Permanent pacemaker (PPM) implantation after heart transplantation (HT) is common, but contemporary data regarding utilization, outcomes, and emerging pacing technologies are limited.
METHODS: We studied PPM placement among 1225 bicaval HT recipients (28% women) treated at our institution from 2010 to 2025 and compared PPM recipients with HT patients without PPMs matched on sex, age, and transplant year.
RESULTS: Median age at HT was 58 years (interquartile range, 48-65 years). Sixty-six (5%) patients received a PPM, with stable implantation rates over time. Median HT-to-PPM time was 4.3 months (interquartile range, 2 weeks to 4.8 years). The main indications were sinus node dysfunction (41 patients, 62%) or atrioventricular block (19 patients, 29%). Median post-HT survival was similar between PPM and non-PPM recipients (12.8 versus 11.5 years, P=0.14). Older organ donor age independently predicted PPM placement (odds ratio, 1.75; P=0.04). After 3.2 years of median follow-up, 1 transvenous PPM had a major complication requiring device extraction. Thirteen (20%) patients received leadless PPMs, including 3 atrial leadless PPMs and 1 dual-chamber leadless PPM. Leadless PPMs had no short-term complications over 1 year of median follow-up.
CONCLUSIONS: Post-HT PPM implantation rates were low and unchanged since 2010. Most devices were implanted for sinus node dysfunction, with 44% implanted within 1 month post-HT. PPM placement was not associated with post-HT survival. Advanced organ donor age was associated with risk of PPM placement. Transvenous PPM complication rates were comparable to rates described in general populations. Leadless PPMs accounted for a substantial minority of PPM placements since their introduction in 2018, with no complications to date. Longer follow-up is needed to establish their long-term outcomes and safety in patients with HT.
METHODS: We studied PPM placement among 1225 bicaval HT recipients (28% women) treated at our institution from 2010 to 2025 and compared PPM recipients with HT patients without PPMs matched on sex, age, and transplant year.
RESULTS: Median age at HT was 58 years (interquartile range, 48-65 years). Sixty-six (5%) patients received a PPM, with stable implantation rates over time. Median HT-to-PPM time was 4.3 months (interquartile range, 2 weeks to 4.8 years). The main indications were sinus node dysfunction (41 patients, 62%) or atrioventricular block (19 patients, 29%). Median post-HT survival was similar between PPM and non-PPM recipients (12.8 versus 11.5 years, P=0.14). Older organ donor age independently predicted PPM placement (odds ratio, 1.75; P=0.04). After 3.2 years of median follow-up, 1 transvenous PPM had a major complication requiring device extraction. Thirteen (20%) patients received leadless PPMs, including 3 atrial leadless PPMs and 1 dual-chamber leadless PPM. Leadless PPMs had no short-term complications over 1 year of median follow-up.
CONCLUSIONS: Post-HT PPM implantation rates were low and unchanged since 2010. Most devices were implanted for sinus node dysfunction, with 44% implanted within 1 month post-HT. PPM placement was not associated with post-HT survival. Advanced organ donor age was associated with risk of PPM placement. Transvenous PPM complication rates were comparable to rates described in general populations. Leadless PPMs accounted for a substantial minority of PPM placements since their introduction in 2018, with no complications to date. Longer follow-up is needed to establish their long-term outcomes and safety in patients with HT.