Journal of the American College of Cardiology · 2005

The extent of perfusion-F18-fluorodeoxyglucose positron emission tomography mismatch determines mortality in medically treated patients with chronic ischemic left ventricular dysfunction.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Desideri Alessandro, Cortigiani Lauro, Christen Alejandra Ines, Coscarelli Sebastian, Gregori Dario, Zanco Pierluigi, Komorovsky Roman, Bax Jeroen J

Аннотация

OBJECTIVES: The purpose of this study was to assess the determinants of mortality in a large group of patients with ischemic cardiomyopathy who are treated medically and the impact of the extent of viable tissue on prognosis.

BACKGROUND: Whether the presence of viability drives mortality in patients with ischemic cardiomyopathy who are treated medically and whether the extent of viability is important are issues that are currently unclear.

METHODS: Two hundred sixty-one patients with ischemic cardiomyopathy underwent positron emission tomography (PET) for assessment of viability. Prospective follow-up was obtained.

RESULTS: Ninety-four patients were revascularized and 167 were not. The cardiac death rate was significantly less in the revascularized patients as compared with medically treated patients (13% vs. 24%, p < 0.05). In the revascularized patients, there was a trend toward better survival in patients with viable myocardium as compared with nonviable myocardium (3.5-year survival, 85% and 75% respectively, p = NS). In the medically treated group, age (hazard ratio [HR] 2.1, 95% confidence interval [CI] 1.2 to 3.7), presence of left bundle branch block (HR 3.4, 95% CI 1.6 to 7.2) and extent of perfusion-metabolism mismatch on PET (HR 1.36, 95% CI 1.1 to 1.6) predicted cardiac death during a median follow-up period of 2.1 years. The risk of cardiac death was not significantly increased when the extent of mismatch was < or =20% (HR 0.97, 95% CI 0.46 to 2.05) but was significantly increased when the extent of mismatch was >20% (HR 3.21, 95% CI 1.38 to 7.49).

CONCLUSIONS: Medically treated patients with ischemic cardiomyopathy and large areas of viable myocardium on PET are at high risk for cardiac death.