OBJECTIVE

This study evaluates the safety and effectiveness of a unique composite thoracic endovascular aneurysm repair (TEVAR) construct (proximal stent graft and distal bare metal stent) for the treatment of patients with complicated type B aortic dissection (cTBAD).

METHODS

In this prospective, single-arm, multicenter study, patients with cTBAD were treated with an endovascular system consisting of proximal TX2 thoracic stent grafts and distal bare metal dissection stents (Zenith Dissection Endovascular System; Cook Medical, Bloomington, Ind). Indications for enrollment were branch vessel malperfusion, impending rupture, aortic diameter ≥40 mm, rapid aortic expansion, and persistent pain or hypertension despite maximum medical therapy. One-year follow-up results, including clinical and radiographic (computerized tomography [CT] and X-ray) evaluation, were available for this report.

RESULTS

Ten centers enrolled 40 patients (70% men; mean age 58 years old) between December 2007 and August 2009. The onset of symptoms was acute (≤14 days) in 24 patients (60%), subacute (15-30 days) in six patients (15%), and chronic (31-90 days) in 10 patients (25%); the overall mean time from symptom onset to treatment was 20 days (range, 0-78 days). A majority of patients (77.5%; 31 of 40 patients) presented with impending aortic rupture (indicated by periaortic effusion/hematoma) or branch vessel malperfusion. Seven combinations of stent grafts and dissection stents were used, and all devices were successfully deployed and patent. The 30-day mortality rate was 5% (2 of 40); two deaths occurred after 30 days, leading to a 1-year survival rate of 90%. Two deaths, occurring at 11 and 81 days postprocedure, respectively, were secondary to aortic rupture. Morbidity occurring within 30 days included stroke (7.5%), transient ischemic attack (2.5%), paraplegia (2.5%), retrograde progression of dissection (5%), and renal failure (12.5%). Additional morbidity after 30 days included one case of retrograde progression of dissection and one case of renal failure. None of the patients with renal failure became dialysis-dependent. Four patients (10%) underwent secondary interventions within 1 year. Favorable aortic remodeling was observed during the course of follow-up, indicated by an increase in the true lumen size and a concomitant decrease in the false lumen size along the dissected aorta, with completely thrombosed thoracic false lumen observed in 31% of patients at 12 months as compared to 0% at baseline.

CONCLUSIONS

Initial data with a composite TEVAR construct have demonstrated favorable clinical and anatomic results. Continued enrollment and long-term data are needed to assess the overall effectiveness of this treatment strategy.

Для цитирования: Lombardi Joseph V, Cambria Richard P, Nienaber Christoph A, Chiesa Roberto, Teebken Omke, Lee Anthony, Mossop Peter, Bharadwaj Priya, STABLE investigators. Prospective multicenter clinical trial (STABLE) on the endovascular treatment of complicated type B aortic dissection using a composite device design.. Journal of vascular surgery. 2011. DOI: 10.1016/j.jvs.2011.10.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.