The Journal of urology · 2003
A prospective randomized trial of the LoFric hydrophilic coated catheter versus conventional plastic catheter for clean intermittent catheterization.
Клиническое исследованиеСравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Vapnek Jonathan M, Maynard Frederick M, Kim Jiensup
Аннотация
PURPOSE: We compared the incidence of hematuria, pyuria and clinical urinary tract infection in patients who performed intermittent self-catheterization using a hydrophilic coated LoFric (Astra Tech AB, Mölndal, Sweden) or standard plastic catheter.
MATERIALS AND METHODS: A total of 62 male patients who performed intermittent self-catheterization to manage neurogenic bladder were randomized into 2 treatment groups at 3 American study sites. Outcome measures included urinary tract infection, microhematuria, pyuria and satisfaction rates.
RESULTS: Of the 62 enrolled patients 49 completed the 12-month study. The withdrawal rate was not different in the 2 groups. At the end of the study there was statistically significantly less hematuria in the hydrophilic coated catheter group compared with controls. In addition, there was a significant decrease in the urinary tract infection rate from baseline in the hydrophilic coated catheter group but not in controls.
CONCLUSIONS: Use of the hydrophilic coated catheter by patients on intermittent self-catheterization is associated with less hematuria and a significant decrease in the incidence of urinary tract infections. Therefore, it may be preferable for some patients, especially those with a history of difficult catheterization, urethral trauma or a high rate of urinary tract infection.
MATERIALS AND METHODS: A total of 62 male patients who performed intermittent self-catheterization to manage neurogenic bladder were randomized into 2 treatment groups at 3 American study sites. Outcome measures included urinary tract infection, microhematuria, pyuria and satisfaction rates.
RESULTS: Of the 62 enrolled patients 49 completed the 12-month study. The withdrawal rate was not different in the 2 groups. At the end of the study there was statistically significantly less hematuria in the hydrophilic coated catheter group compared with controls. In addition, there was a significant decrease in the urinary tract infection rate from baseline in the hydrophilic coated catheter group but not in controls.
CONCLUSIONS: Use of the hydrophilic coated catheter by patients on intermittent self-catheterization is associated with less hematuria and a significant decrease in the incidence of urinary tract infections. Therefore, it may be preferable for some patients, especially those with a history of difficult catheterization, urethral trauma or a high rate of urinary tract infection.