m+Medelevator.RU
← Поиск публикаций
Journal of cardiothoracic surgery · 2015

Posterior mitral annuloplasty for enhancing mitral leaflet coaptation: using a strip designed for placement in the posterior annulus.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kim Jong Hun, Kim Kyung Hwa, Choi Jong Bum, Kuh Ja Hong

Аннотация

BACKGROUND: In patients with mitral valve regurgitation (MR), posterior mitral annuloplasty (PMA) was performed for mitral valve repair using a strip designed for placement in the posterior annulus, sparing the anterior annulus and anterior half of the commissures.

METHODS: Between September 2009 and October 2013, we performed PMA using a novel strip in 74 consecutive patients with MR greater than 3+. Procedures associated with mitral valve repairs were performed in 41 patients (56.9 %), including new chord placement for leaflet prolapse (n=30), patch valvuloplasty for posterior chord rupture (n=4), and posterior leaflet augmentation (n=15). All patients were analyzed by serial echocardiographic follow-up, and preoperative and postoperative computed tomography was performed in 10 randomly selected patients.

RESULTS: Hospital death occurred in two patients (2.7 %), and 72 survived patients were completely followed up. At a mean follow-up of 37.2 ± 15.0 months, the MR grade was zero or 1+ in 64 patients (88.9 %), 2+ in 7 patients (9.7 %), and 3+ in one patient (1.4 %). The mean indexed valve area and mean valve gradient were 1.7 ± 0.4 cm(2)/m(2) and 3.5 ± 1.2 mmHg, respectively. The mean leaflet coaptation height in early systole was 12.8 ± 3.5 mm. During the cardiac cycle, the repaired valves exhibited dynamic changes of 19.5 ± 9.3 % in the septo-lateral dimensions. No early conversions to valve replacements or late reoperations occurred. None of the patients with remnant or recurrent MR experienced hemolysis.

CONCLUSIONS: PMA using a novel strip showed a sufficient coaptation height secondary to reduction of the septo-lateral annular dimensions and dynamic changes in the dimensions. It can be expected to be an alternative mitral annuloplasty technique with satisfactory results.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты