MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1067/mob.2002.124841

Медицинская библиотека · American journal of obstetrics and gynecology · 2002

Predicting postoperative voiding efficiency after operation for incontinence and prolapse.

Kleeman Steven, Goldwasser Steven, Vassallo Brett, Karram Mickey

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The purpose of this study was to determine the postoperative postvoid residual volume that predicts a voiding efficiency after operation for incontinence and prolapse.

STUDY

DESIGN

Ninety-nine patients met the criteria for inclusion. The patients' bladders were filled retrograde through gravity, through a Foley catheter, with 300 mL of sterile water, or by subjective fullness. The catheter was then removed, and the patient was asked to void spontaneously into a measured urine collection device ("Texas hat"). A postvoid residual was then calculated (amount voided minus amount inserted). The Foley catheter was reinserted for patients with a postvoid residual of >50%. These patients were instructed to follow-up in the office in 1 week, at which time the test was repeated. This process continued until the patient had a postvoid residual of < or = 50% or was taught intermittent self-catheterization.

RESULTS

Ninety patients were available for follow-up. The overall failure rate (defined as cases that required reinsertion of a catheter) was 7.8%. No patient with a postvoid residual of < or = 32% required reinsertion of a catheter.

CONCLUSION

With the use of this simple bedside test, voiding efficiency was predicted in 92% of patients who voided > or = 50% of the amount inserted and in 100% of patients who voided > or = 68%.

Для цитирования: Kleeman Steven, Goldwasser Steven, Vassallo Brett, Karram Mickey. Predicting postoperative voiding efficiency after operation for incontinence and prolapse.. American journal of obstetrics and gynecology. 2002. DOI: 10.1067/mob.2002.124841.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.