Pulmonary Vein-to-Pulmonary Artery Ratio is an Echocardiographic Index of Congestive Heart Failure in Dogs with Degenerative Mitral Valve Disease.
Аннотация
BACKGROUND
Early recognition of left-sided congestive heart failure (CHF) in dogs with degenerative mitral valve disease (DMVD) is important because it influences medical therapy, timing of follow-up, and outcome.
HYPOTHESIS: Pulmonary vein diameter-to-pulmonary artery diameter ratio (PV/PA) measured by echocardiography can predict CHF.
ANIMALS: Ninety-eight client-owned dogs, 37 controls, and 61 dogs with DMVD.
METHODS
Prospective clinical cohort study. History, physical examination and Doppler-echocardiography were performed. Dogs were classified as International Small Animal Cardiac Health Council class I, II or III. Congestive heart failure was identified in a subset of 56 dogs based on radiographic findings. The PV/PA was measured in bidimensional (2D) and M-mode by 2 investigators blinded to the radiologists' conclusions.
RESULTS
Interobserver coefficients of variation for PV/PA acquisition and measurement were <10%. The PV/PA in control dogs was approximately 1 and increased with class of heart failure. The presence of CHF could be best predicted by measuring PV/PA in 2D echocardiography (cut-off, 1.7; area under the curve, 0.98; CI, 0.97-0.98; P < .001) with a sensitivity of 96% and a specificity of 91%.
CONCLUSION AND CLINICAL
IMPORTANCE
The PV/PA is a simple and reproducible echocardiographic variable that increases with class of heart failure and may help discriminate dogs in CHF from asymptomatic dogs with DMVD. Additional studies are required to determine whether PV/PA might provide additional information in the integrated interpretation of Doppler-echocardiographic indices of left ventricular filling pressures and could be used for rapid assessment of CHF in dogs in a critical care setting.