MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10840-023-01594-w

Медицинская библиотека · Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2023

Electrogram morphology recurrence guided catheter ablation for repeat ablation of persistent atrial fibrillation.

Mitrani Raul D, Zaatari Ghaith, Bohorquez Jorge, Ng Jason, Ng Justin, Rivner Harold, Velasquez Alex, Lambrakos Litsa, Arora Rishi, Goldberger Jeffrey J

СтатьяПеревод в очереди

Аннотация

BACKGROUND

There are no standard mapping approaches for patients with persistent atrial fibrillation (PeAF), particularly after failed prior catheter ablation (CA). In this study, we assess the feasibility of using Electrogram Morphology Recurrence (EMR) to guide ablation.

METHODS

Ten patients with recurrent PeAF after prior CA underwent detailed mapping of both atria during PeAF using the PentaRay (4 mm interelectrode spacing) and 3D mapping with CARTO. At each site, 15 s recordings were made. Custom software identified each electrogram and cross-correlation was used to identify the most recurrent electrogram morphology from which the % recurrence and cycle length of the most repeatable morphology (CLR) was calculated. Sites of shortest CLR and sites within 5 ms of shortest CLR with recurrence ≥ 80% were used to inform CA strategy.

RESULTS

A mean of 342.9 ± 131.9 LA and 328.6 ± 91.5 RA sites were recorded per patient. Nine had PV reconnection. Shortest CLR sites guided ablation in 6/10 patients while 1 patient failed to fulfill shortest CLR criteria, and another 3 did not undergo CA guided by shortest CLR due to operator preference. On 12-month follow-up, all 4 patients without shortest CLR guided CA had recurrent PeAF. Of the 6 patients with shortest CLR guided CA, 5 patients did not have recurrent PeAF (p = 0.048), although 1 had paroxysmal AF and 2 had atypical atrial flutter.

CONCLUSION

EMR is a feasible, novel technique to guide CA in patients with PeAF. Further evaluation is needed to provide an electrogram-based method for mapping guided targeted ablation of key areas.

Для цитирования: Mitrani Raul D, Zaatari Ghaith, Bohorquez Jorge, Ng Jason, Ng Justin, Rivner Harold, Velasquez Alex, Lambrakos Litsa, Arora Rishi, Goldberger Jeffrey J. Electrogram morphology recurrence guided catheter ablation for repeat ablation of persistent atrial fibrillation.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2023. DOI: 10.1007/s10840-023-01594-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.