m+Medelevator.RU
← Поиск публикаций
The Australian & New Zealand journal of obstetrics & gynaecology · 2016

Involving the consultant before fetal blood sampling.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lowe Belinda, Beckmann Michael

Аннотация

BACKGROUND: Fetal scalp lactate (FSL) is used when the cardiotocography (CTG) is not normal in an attempt to reduce the false-positive rate and the likelihood of unnecessary intervention. Whilst the test has almost a 100% negative predictive value, the positive predictive value of this test is very low.

AIMS: To measure the effect of introducing consultant obstetrician review of every abnormal CTG prior to the decision to perform FSL.

MATERIALS AND METHODS: A retrospective cohort study was performed using routinely collected de-identified data. Mode of birth outcomes for women who had a continuous CTG in labour were compared in two equal time periods, 12 months before and after a change in hospital policy. Change in hospital policy dictated that FSL was only performed on a pathological CTG after consultant obstetrician review of the CTG.

RESULTS: Consultant obstetrician review of CTG prior to FSL was associated with fewer FSL performed (1.7% vs 3.5%; P ≤ 0.01), fewer babies acidaemic at birth pH < 7.1 (0.8% vs 2.2%; P < 0.01), fewer caesarean sections for presumed fetal distress (CS for FD) (6.6% vs 8.1%; P = 0.05) and fewer instrumental births (17.6% vs 20%; P = 0.04). When adjusted for confounders, the change in policy was independently associated with a reduced likelihood of CS for FD (adjusted odds ratios = 0.78 (0.63-0.97); P = 0.03).

CONCLUSIONS: A hospital policy whereby a consultant obstetrician reviews abnormal CTGs prior to performing FSL may help to increase the pretest probability and reduce the rate of CS for FD, as well as instrumental birth and unnecessary FSL.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты