m+Medelevator.RU
← Поиск публикаций
European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 1995

Technetium99m-sestamibi scanning before initial neck exploration in patients with primary hyperparathyroidism.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Bugis S P, Berno E, Rusnak C H, Chu D

Аннотация

Technetium99m (Tc) sestamibi(mibi) has been proposed as an alternative to the standard radionuclide imaging technique of thallium 201 chloride-99mTc pertechnetate subtraction scan (TTS) in patients with primary hyperparathyroidism. In the present study, mibi was evaluated as an alternative to TTS in 37 patients who had either mibi-99mTc pertechnetate subtraction scans, mibi-iodine123 (I) subtraction scans or mibi single isotope washout scans. There were 30 females and 7 males with an average age of 57 years (range, 27-78 years). Parathyroid adenomas were found in 35 patients and hyperplasia in 2. Twenty-eight mibi scans were positive and 25 of these correctly localized the parathyroid abnormality for a sensitivity of 68% (25 of 37) and a positive predictive value of 89% (25 of 28). There were 3 false-positives (8%) and 9 false-negatives (25%). The scan was not helpful in either patient with parathyroid gland hyperplasia. Mibi-123I subtraction was the most accurate scan and was diagnostic clinically in all 7 patients studied. Mibi scans were significantly more likely to identify inferior rather than superior adenomas (P = 0.01). Twenty-seven of the 37 patients also had a TTS which was correct in only 37% of cases while the mibi scan was correct in 68% (P = 0.02). However, routine use of nuclear scanning with mibi was still not supported by these data. Further clinical evaluation of various techniques may improve accuracy. Since mibi was significantly more accurate than TTS, it should be considered preferentially when radionuclide imaging is used in patients with recurrent hyperparathyroidism.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты