MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · The American journal of gastroenterology · 1997

Value of Doppler ultrasound parameters of portal vein and hepatic artery in the diagnosis of cirrhosis and portal hypertension.

Iwao T, Toyonaga A, Oho K, Tayama C, Masumoto H, Sakai T, Sato M, Tanikawa K

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

This prospective study was designed to assess the sensitivity and specificity of Doppler ultrasound parameters in the diagnosis of cirrhosis and portal hypertension.

METHODS

Portal and hepatic arterial Doppler ultrasound was performed on 76 patients with cirrhosis and esophageal varices and on 73 age- and sex-matched controls. The parameters evaluated were portal venous velocity and hepatic arterial pulsatility index. The liver vascular index was calculated as the ratio of portal venous velocity to hepatic arterial pulsatility index.

RESULTS

Portal venous velocity was significantly lower (11.0 +/- 2.4 vs 15.9 +/- 2.8 cm/s, p < 0.001) and hepatic arterial pulsatility index was significantly higher (1.28 +/- 0.18 vs 0.95 +/- 0.17,p < 0.001) in patients than in controls. Thus, the liver vascular index was significantly lower in patients than in controls (8.7 +/- 2.1 vs 17.2 +/- 4.3 cm/s, p < 0.001). The sensitivity and specificity of these parameters in the detection of cirrhosis and portal hypertension was then analyzed with the receiver operating characteristic curve. The best cut-off values were considered to be 13 cm/se of portal venous velocity and 1.1 of hepatic arterial pulsatility index, showing a sensitivity and specificity of 83, 85, 84, and 81%, respectively. The best cut-off value of the liver vascular index was 12 cm/s with a sensitivity and specificity of 97 and 93%, respectively.

CONCLUSIONS

The liver vascular index is a high sensitive and specific Doppler ultrasound parameter in the diagnosis of cirrhosis and portal hypertension.

Для цитирования: Iwao T, Toyonaga A, Oho K, Tayama C, Masumoto H, Sakai T, Sato M, Tanikawa K. Value of Doppler ultrasound parameters of portal vein and hepatic artery in the diagnosis of cirrhosis and portal hypertension.. The American journal of gastroenterology. 1997.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.