European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2022
Long-term outcomes after aortic valve replacement using a 19-mm bioprosthesis.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Okamura Homare, Kusadokoro Sho, Mieno Makiko, Kimura Naoyuki, Yamaguchi Atsushi
Аннотация
OBJECTIVES: Transcatheter aortic valve replacement is known to be associated with improved haemodynamics in patients with aortic stenosis and a small aortic annulus. However, limited benchmark data are available regarding the long-term outcomes in patients treated with surgical aortic valve replacement (SAVR). We investigated the long-term outcomes of SAVR using a 19-mm bioprosthesis.
METHODS: This study included consecutive patients who underwent SAVR using a 19-mm bioprosthesis at our hospital between 2008 and 2012.
RESULTS: In a total of 132 patients, moderate and severe prosthesis-patient mismatch occurred in 36 (27.3%) and 7 patients (5.3%), respectively. The median follow-up period was 7.7 years. The overall 5- and 10-year survival rates were 79.4% and 52.9%, respectively. The 5- and 10-year freedom from major adverse valve-related events rates were 89.6% and 74.2%, respectively. Neither moderate nor severe prosthesis-patient mismatch was associated with late mortality, major adverse valve-related events or heart failure. Follow-up echocardiographic data were obtained at a median interval of 4.8 years in 80% of patients who survived ≥6 months postoperatively. Follow-up echocardiographic data showed a significantly increased left ventricular ejection fraction, decreased mean transvalvular/transprosthetic pressure gradients and a decreased mean left ventricular mass. At follow-up, we observed moderate or severe haemodynamic structural valve deterioration in 17 patients; however, structural valve deterioration did not affect late survival or freedom from major adverse valve-related events rates, or heart failure.
CONCLUSIONS: SAVR using the 19-mm bioprosthesis was associated with satisfactory long-term clinical and haemodynamic outcomes.
METHODS: This study included consecutive patients who underwent SAVR using a 19-mm bioprosthesis at our hospital between 2008 and 2012.
RESULTS: In a total of 132 patients, moderate and severe prosthesis-patient mismatch occurred in 36 (27.3%) and 7 patients (5.3%), respectively. The median follow-up period was 7.7 years. The overall 5- and 10-year survival rates were 79.4% and 52.9%, respectively. The 5- and 10-year freedom from major adverse valve-related events rates were 89.6% and 74.2%, respectively. Neither moderate nor severe prosthesis-patient mismatch was associated with late mortality, major adverse valve-related events or heart failure. Follow-up echocardiographic data were obtained at a median interval of 4.8 years in 80% of patients who survived ≥6 months postoperatively. Follow-up echocardiographic data showed a significantly increased left ventricular ejection fraction, decreased mean transvalvular/transprosthetic pressure gradients and a decreased mean left ventricular mass. At follow-up, we observed moderate or severe haemodynamic structural valve deterioration in 17 patients; however, structural valve deterioration did not affect late survival or freedom from major adverse valve-related events rates, or heart failure.
CONCLUSIONS: SAVR using the 19-mm bioprosthesis was associated with satisfactory long-term clinical and haemodynamic outcomes.