m+Medelevator.RU
← Поиск публикаций
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2021

The Allegra transcatheter heart valve: Short term results from a multicenter registry.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wolfrum Mathias, Moccetti Federico, Piuhola Jarkko, Lehtola Heidi, Baz José Antonio, Iñiguez Andrés, van Nunen Lokien X, Tonino Pim A L, Niemelä Matti, Toggweiler Stefan

Аннотация

OBJECTIVES: We aimed to determine the safety and efficacy of the Allegra transcatheter heart valve (THV) for the treatment of severe aortic valve stenosis in a large patient population treated under real-world conditions.

BACKGROUND: The Allegra is a novel self-expanding THV with supra-annular bovine leaflets. The valve is available in three different sizes (23, 27, and 31 mm), all are delivered through an 18F sheath.

METHODS: Consecutive patients undergoing TAVR with the Allegra THV were enrolled in a multicenter-registry. Data were collected throughout initial hospital-stay and at 30-day follow-up. Clinical endpoints were defined according to the updated definitions of the Valve-Academic-Research-Consortium.

RESULTS: This registry included 255 patients (mean age 83 ± 6 years, 48% women) from four European centers. Median European System for Cardiac Operative Risk Evaluation II score (EuroSCORE II) was 3.3% (IQR 1.9-5.8%). Acute device success was 95.7%. The remaining 11 patients had either moderate paravalvular regurgitation immediately after the procedure (7 patients) or the device could not be optimal positioned requiring implantation of a second THV (4 patients). Major vascular complications and major/life-threatening bleedings occurred in 10 (3.9%) and 12 (4.7%) patients, respectively. At 30 day follow-up, mean effective orifice area was 2.2 ± 0.5 cm2 , mean gradient was 6.9 ± 3.8 mmHg, 7 (3.3%) patients had more than mild paravalvular leakage, 3 patients (1.2%) had died, 6 patients (2.4%) had a stroke and 30 (12.8%) patients had required implantation of a new permanent pacemaker.

CONCLUSIONS: Transfemoral implantation of the Allegra THV resulted in favorable clinical and echocardiographic outcomes during hospitalization and short-term follow up.