MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/cid.13392

Медицинская библиотека · Clinical implant dentistry and related research · 2024

Full-arch prostheses supported by implants with different macrostructures: A multicenter randomized controlled trial.

Marcantonio Ana Carolina Monachini, de Oliveira Guilherme José Pimentel Lopes, Tassi Paulo Afonso, Manfrinato João Paulo Lavagnoli, Segnini Bruno, de Souza Bezerra Araújo Raphael Ferreira, Trojan Larissa Carvalho, Fontão Flávia Noemy Gasparini Kiatake, de Mattias Sartori Ivete Aparecida, Sartori Elisa Mattias, Padovan Luis Eduardo Marques, Zandim-Barcelos Daniela Leal, Marcantonio Elcio

СтатьяРандомизированное исследованиеМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study evaluates the clinical performance of implants with hydrophilic surface and two different macrostructures: cylindrical with perforating triangular threads (CT) and cylindrical-tapered with the association of square and condensing and perforating triangular threads (TST).

MATERIALS AND

METHODS

This was a multicenter split-mouth, simple-blinded, randomized, and controlled trial. Thirty patients with edentulous mandible received two CT and two TST implants. Primary stability was determined by insertion torque and resonance frequency analysis (RFA). Implants were loaded with full fixed-arch prostheses within 24 h after insertion. Clinical parameters (visible plaque index, marginal bleeding index; bleeding on probing; probing depth; and clinical attachment level) and the RFA were assessed at 2, 6, 12, and 24 months after implant loading. Marginal bone level changes were measured by comparison of standardized radiographs taken on the day of implant placement and 6, 12, and 24 months thereafter.

RESULTS

Twenty-eight patients completed the 2-year follow-up. The survival rates were 99.16% for CT implants and 100% for TST implants. One CT implant was lost until the 2 months follow-up. No significant differences were found between the two implant types for marginal bone level changes (CT 0.34 [0.24; 0.55 mm]; 0.33 [0.18; 0.55 mm]; 0.41 [0.12; 0.7 mm] vs TST 0.36 [0.14; 0.74 mm]; 0.33 [0.23; 0.63 mm]; 0.30 [0.20; 0.64 mm] at 6, 12, and 24 months, respectively) and other clinical parameters.

CONCLUSION

The macrostructure of the implants had no influence on survival rate, primary and secondary stability, marginal bone level changes, and peri-implant clinical parameters outcomes. Both implants can be predictably used for immediate loading of full-arch mandibular prostheses.

Для цитирования: Marcantonio Ana Carolina Monachini, de Oliveira Guilherme José Pimentel Lopes, Tassi Paulo Afonso, Manfrinato João Paulo Lavagnoli, Segnini Bruno, de Souza Bezerra Araújo Raphael Ferreira, Trojan Larissa Carvalho, Fontão Flávia Noemy Gasparini Kiatake, de Mattias Sartori Ivete Aparecida, Sartori Elisa Mattias, Padovan Luis Eduardo Marques, Zandim-Barcelos Daniela Leal, Marcantonio Elcio. Full-arch prostheses supported by implants with different macrostructures: A multicenter randomized controlled trial.. Clinical implant dentistry and related research. 2024. DOI: 10.1111/cid.13392.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.