m+Medelevator.RU
← Поиск публикаций
The Journal of heart valve disease · 2002

In-vivo analysis of the instantaneous transvalvular pressure difference-flow relationship in aortic valve stenosis: implications of unsteady fluid-dynamics for the clinical assessment of disease severity.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Bermejo Javier, Antoranz J Carlos, Burwash Ian G, Alvarez Jose L Rojo, Moreno Mar, García-Fernández Miguel A, Otto Catherine M

Аннотация

BACKGROUND AND AIM OF THE STUDY: Because the hemodynamic basis of aortic valve area (AVA) has never been validated in vivo, several alternative indices have been proposed to quantify the severity of aortic stenosis (AS). This study was designed to assess the fluid-dynamics of aortic valve stenosis in order to clarify which index best accounts for disease severity. The diagnostic implications of reversed deltaP during ejection were also investigated.

METHODS: Chronic valvular AS characterized by stiff leaflets without commissural fusion was created surgically in eight adult mongrel dogs; three additional animals were used as controls. At two-week intervals (three studies per dog), simultaneous micromanometer pressure and transit-time Q measurements were collected under different hemodynamic conditions. Instantaneous deltaP and Q signals were processed digitally and fitted to a modified form of the unsteady Bernoulli equation in which AS is characterized by effective valve area.

RESULTS: An unsteady Bernoulli equation accurately predicted measured instantaneous AP values (R = 0.97+/-0.06), and a quadratic correlation was observed between instantaneously fitted and Gorlin-derived AVA. Additionally, deltaP < 0 mmHg during late ejection was observed in the majority of AS datasets, with a normalized time to deltaP reversal of 93+/-13% for AS animals versus 69+/-36% for controls (p <0.0005). Time to deltaP reversal inversely correlated with the Strouhal number (R = -0.77), and was responsible for an overestimation of mean systolic transvalvular deltaP and Q that resulted in a significant bias in the Gorlin method. Error was highest in moderate stenosis with low transvalvular output.

CONCLUSION: Unsteady fluid-dynamics supports AVA over other measures of AS such as aortic valve resistance. However importantly, late-ejection reversal of deltaP precludes estimating the systolic ejection period from pressure tracings, and accounts for an additional source of error when AS is quantified invasively.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты