MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Italian heart journal : official journal of the Italian Federation of Cardiology · 2002

Reliability of new and old Doppler echocardiographic indexes of the severity of aortic stenosis in patients with a low cardiac output.

Antonini-Canterin Francesco, Huang Guoqian, Cervesato Eugenio, Faggiano Pompilio, Pavan Daniela, Piazza Rita, Burelli Claudio, Cassin Matteo, Macor Franco, Zardo Fabio, Nicolosi Gian Luigi

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

In addition to the conventional "flow-corrected" parameters (continuity equation and aortic valve resistance), new and simpler Doppler echocardiographic indexes of the severity of aortic stenosis have recently been introduced. These measures can be classified as "function-corrected" indexes (fractional shortening-velocity ratio and ejection fraction-velocity ratio) and "pressure-corrected" indexes (percent stroke work loss). Little information however is available about the diagnostic accuracy of each of these parameters in identifying patients with severe aortic stenosis in low-flow states, in which the diagnosis and clinical decision-making are more difficult and challenging.

METHODS

We analyzed 161 patients with aortic stenosis (96 males, 65 females, mean age 68 +/- 9 years) and a low cardiac output (thermodilution cardiac index < or = 2.5 l/min/m2). All patients underwent both cardiac catheterization and echocardiography within 48 hours one of the other. The invasive Gorlin valve area was used as gold standard (severe aortic stenosis = Gorlin < or = 0.8 cm2). Echocardiographic indexes were assessed by an investigator who was unaware of the hemodynamic findings.

RESULTS

The mean Gorlin aortic valve area was 0.7 +/- 0.3 cm2; cardiac catheterization allowed the identification of 129 patients with severe aortic stenosis and of 32 with mild-to-moderate aortic stenosis. The diagnostic accuracy of the Doppler gradient alone was low (sensitivity 55%). The best linear correlation with the Gorlin value was found using the "function-corrected" ejection fraction-velocity ratio (r = 0.85). Similarly, the best combination of sensitivity and specificity in identifying patients with severe aortic stenosis, as assessed by cardiac catheterization, was observed using the ejection fraction-velocity ratio (sensitivity 87%, specificity 88%).

CONCLUSIONS

In patients with aortic stenosis and a low cardiac output, the "function-corrected" ejection fraction-velocity ratio offers the better diagnostic accuracy, as compared with the cardiac catheterization valve area calculation.

Для цитирования: Antonini-Canterin Francesco, Huang Guoqian, Cervesato Eugenio, Faggiano Pompilio, Pavan Daniela, Piazza Rita, Burelli Claudio, Cassin Matteo, Macor Franco, Zardo Fabio, Nicolosi Gian Luigi. Reliability of new and old Doppler echocardiographic indexes of the severity of aortic stenosis in patients with a low cardiac output.. Italian heart journal : official journal of the Italian Federation of Cardiology. 2002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.