Медицинская библиотека · Heart rhythm · 2019

Automated intraprocedural localization of origin of ventricular activation using patient-specific computed tomographic imaging.

Zhou Shijie, Sapp John L, Horáček B Milan, Warren James W, MacInnis Paul J, Davis Jason, Elsokkari Ihab, Choudhury Rajin, Parkash Ratika, Gray Chris, Gardner Martin, MacIntyre Ciorsti J, AbdelWahab Amir

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

To facilitate catheter ablation of ventricular tachycardia (VT), we previously developed an automated method to identify sources of left ventricular (LV) activation in real time using 12-lead electrocardiography (ECG), the accuracy of which depends on acquisition of a complete electroanatomic (EA) map.

OBJECTIVE

The purpose of this study was to assess the feasibility of using a registered cardiac computed tomogram (CT) rather than an EA map to permit real-time localization and avoid errors introduced by incomplete maps.

METHODS

Before LV VT ablation, 10 patients underwent CT imaging and 3-dimensional reconstruction of the cardiac surface to create a triangle mesh surface, which was registered to the EA map during the procedure and imported into custom localization software. The software uses QRS integrals from leads III, V2, and V6; derives personalized regression coefficients from pacing at ≥5 sites with known locations; and estimates the location of unknown activation sites on the 3-dimensional patient-specific LV endocardial surface. Localization accuracy was quantified for VT exit sites in millimeters by comparing the calculated against the known locations.

RESULTS

The VT exit site was identified for 20 VTs using activation and entrainment mapping, supplemented by pace-mapping at the scar margin. The automated localization software achieved incremental accuracy with additional pacing sites and had a mean localization error of 6.9 ± 5.7 mm for the 20 VTs.

CONCLUSION

Patient-specific CT geometry is feasible for use in real-time automated localization of ventricular activation and may avoid reliance on a complete EA map.

Для цитирования: Zhou Shijie, Sapp John L, Horáček B Milan, Warren James W, MacInnis Paul J, Davis Jason, Elsokkari Ihab, Choudhury Rajin, Parkash Ratika, Gray Chris, Gardner Martin, MacIntyre Ciorsti J, AbdelWahab Amir. Automated intraprocedural localization of origin of ventricular activation using patient-specific computed tomographic imaging.. Heart rhythm. 2019. DOI: 10.1016/j.hrthm.2019.10.025.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.