European heart journal. Case reports · 2019
New implications for the recurrence mechanism of an upper septal ventricular tachycardia: a case report.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yamaguchi Junji, Nagata Yasutoshi, Yamauchi Yasuteru, Hirao Kenzo
Аннотация
BACKGROUND: Verapamil-sensitive fascicular ventricular tachycardia (VT) is the most common type of idiopathic left ventricular tachycardia, and it is divided into three types. Upper septal ventricular tachycardia (US-VT) is likely in patients with prior episodes of left posterior fascicular (LPF)-VT ablation, however, little is known about the recurrence mechanism of US-VT.
CASE SUMMARY: A 53-year-old man had an US-VT after two catheter ablation sessions for a common idiopathic LPF-VT. The US-VT was successfully treated by ablating the proximal site of the LPF without making any further branch or fascicular block. This successful ablation point corresponded completely with the earliest pre-systolic potential (P2) site of the LPF-VT during the 1st session of catheter ablation.
DISCUSSION: An US-VT recurrence could occur if a critical slow conduction is not affected by the catheter ablation. This recurrence might be the result of changing the re-entrant circuit after damage to the LPF. In order to eliminate the LPF-VT and prevent an US-VT recurrence, the earliest P2 site should be investigated carefully and ablated sufficiently.
CASE SUMMARY: A 53-year-old man had an US-VT after two catheter ablation sessions for a common idiopathic LPF-VT. The US-VT was successfully treated by ablating the proximal site of the LPF without making any further branch or fascicular block. This successful ablation point corresponded completely with the earliest pre-systolic potential (P2) site of the LPF-VT during the 1st session of catheter ablation.
DISCUSSION: An US-VT recurrence could occur if a critical slow conduction is not affected by the catheter ablation. This recurrence might be the result of changing the re-entrant circuit after damage to the LPF. In order to eliminate the LPF-VT and prevent an US-VT recurrence, the earliest P2 site should be investigated carefully and ablated sufficiently.