MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.gaitpost.2015.12.039

Медицинская библиотека · Gait & posture · 2015

In-shoe plantar pressure measurements for the evaluation and adaptation of foot orthoses in patients with rheumatoid arthritis: A proof of concept study.

Tenten-Diepenmaat Marloes, Dekker Joost, Steenbergen Menno, Huybrechts Elleke, Roorda Leo D, van Schaardenburg Dirkjan, Bus Sicco A, van der Leeden Marike

СтатьяНаблюдательное исследованиеПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

Improving foot orthoses (FOs) in patients with rheumatoid arthritis (RA) by using in-shoe plantar pressure measurements seems promising. The objectives of this study were to evaluate (1) the outcome on plantar pressure distribution of FOs that were adapted using in-shoe plantar pressure measurements according to a protocol and (2) the protocol feasibility.

METHODS

Forty-five RA patients with foot problems were included in this observational proof-of concept study. FOs were custom-made by a podiatrist according to usual care. Regions of Interest (ROIs) for plantar pressure reduction were selected. According to a protocol, usual care FOs were evaluated using in-shoe plantar pressure measurements and, if necessary, adapted. Plantar pressure-time integrals at the ROIs were compared between the following conditions: (1) no-FO versus usual care FO and (2) usual care FO versus adapted FO. Semi-structured interviews were held with patients and podiatrists to evaluate the feasibility of the protocol.

RESULTS

Adapted FOs were developed in 70% of the patients. In these patients, usual care FOs showed a mean 9% reduction in pressure-time integral at forefoot ROIs compared to no-FOs (p=0.01). FO adaptation led to an additional mean 3% reduction in pressure-time integral (p=0.05). The protocol was considered feasible by patients. Podiatrists considered the protocol more useful to achieve individual rather than general treatment goals. A final protocol was proposed.

CONCLUSIONS

Using in-shoe plantar pressure measurements for adapting foot orthoses for patients with RA leads to a small additional plantar pressure reduction in the forefoot. Further research on the clinical relevance of this outcome is required.

Для цитирования: Tenten-Diepenmaat Marloes, Dekker Joost, Steenbergen Menno, Huybrechts Elleke, Roorda Leo D, van Schaardenburg Dirkjan, Bus Sicco A, van der Leeden Marike. In-shoe plantar pressure measurements for the evaluation and adaptation of foot orthoses in patients with rheumatoid arthritis: A proof of concept study.. Gait & posture. 2015. DOI: 10.1016/j.gaitpost.2015.12.039.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.