m+Medelevator.RU
← Поиск публикаций
Ophthalmology. Retina · 2025

Two-Year Visual, Refractive, and Anatomical Outcomes of Sutureless, Intrascleral, 1-Piece Intraocular Lens Fixation: A Prospective Study.

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Marolo Paola, Parisi Guglielmo, Conte Fabio, Cimorosi Francesca, Tibaldi Davide, Fallico Matteo, Toro Mario Damiano, Borrelli Enrico, Motta Lorenzo, Vaiano Agostino S, Reibaldi Michele

Аннотация

PURPOSE: To evaluate the 2-year visual, refractive, and anatomical outcomes of a foldable single-piece intraocular lens (IOL) specifically designed for sutureless intrascleral fixation in eyes without adequate capsular support.

DESIGN: Prospective, observational, multicenter study.

PARTICIPANTS: Two hundred thirty-four eyes of 232 patients undergoing secondary IOL implantation using a standardized sutureless intrascleral fixation technique.

METHODS: All eyes received a foldable, 1-piece acrylic IOL implanted via a scleral flap technique. Best-corrected visual acuity (BCVA), spherical equivalent (SE), refractive prediction error (PE), and endothelial cell density (ECD) were assessed at baseline, 12 months, and 24 months. A subgroup analysis using anterior segment OCT evaluated IOL tilt, decentration, and surgically induced astigmatism (SIA), Multivariate regression explored biometric predictors of refractive outcomes.

MAIN OUTCOME MEASURES: Changes in BCVA, refractive stability, PE, IOL tilt and decentration, ECD, and postoperative complications.

RESULTS: Mean BCVA improved from 0.74 ± 0.30 to 0.26 ± 0.24 logMAR at 24 months (P < 0.001). Spherical equivalent changed from 3.52 ± 5.92 diopters (D) at baseline to -0.33 ± 0.85 D at 24 months (P < 0.001). A PE within ±1.00 D was achieved in 77% of eyes. Mean absolute SIA remained stable (0.86 ± 0.44 D at 12 months vs. 0.90 ± 0.62 D at 24 months; P = 0.911). Intraocular lens tilt and decentration showed no significant change over time. ECD was preserved (P = 0.895). Visual decline occurred in 2.56% of eyes and no cases of IOL dislocation or endophthalmitis were observed.

CONCLUSIONS: Sutureless intrascleral fixation of a single-piece foldable IOL may lead to sustained visual improvement, high refractive accuracy, stable anatomical positioning, and a low rate of complications over 24 months. This technique demonstrates good tolerability and is associated with favorable visual outcomes for secondary implantation in eyes lacking capsular support.

FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты