MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.apradiso.2022.110339

Медицинская библиотека · Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2022

Effective dose for kidney-ureter-bladder plain radiography, intravenous urography, and abdominal computed tomography scan: A phantom study.

Hsieh Tzuo-Yi, Chen Sung-Lang, Chang Yi-Ru, Tyan Yeu-Sheng, Chen Tou-Rong

СтатьяПеревод пока не подготовлен

Аннотация

Abdominal colic pain or hematuria is suspected to be caused by urinary tract stones. Commonly used X-ray examinations include kidney-ureter-bladder plain radiography (KUB), intravenous urography (IVU), and abdominal computed tomography (CT). In this study, a high-sensitivity thermoluminescent dosimeter (TLD) was embedded in a Rando phantom to directly measure organ dose and evaluate effective dose. During each experiment, 139 TLD measurement points that cover almost all organs (as recommended by the ICRP 103 report) were examined. Red bone-marrow and remainder tissues have a high tissue weighting factor (0.12), and they are widely distributed. In the phantom, 34 TLDs and 31 TLDs were embedded in the red bone-marrow and remainder tissues to improve the accuracy and representativeness of organ doses. The detailed organ dose distributions for KUB, IVU, and abdominal CT are presented. The effective doses for KUB and IVU were 0.22 and 1.51 mSv, respectively, and those for two abdominal CTs were 8.21 and 9.27 mSv. This experiment presents a conversion factor of 0.0177 mSv·mGy-1 cm-1 for the abdominal CT examination, which differs from most of the conversion factors obtained through the Monte Carlo simulation method.

Для цитирования: Hsieh Tzuo-Yi, Chen Sung-Lang, Chang Yi-Ru, Tyan Yeu-Sheng, Chen Tou-Rong. Effective dose for kidney-ureter-bladder plain radiography, intravenous urography, and abdominal computed tomography scan: A phantom study.. Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine. 2022. DOI: 10.1016/j.apradiso.2022.110339.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.