MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/neurintsurg-2019-014874

Медицинская библиотека · Journal of neurointerventional surgery · 2019

Early post-Humanitarian Device Exemption experience with the Neuroform Atlas stent.

Tsai Jenny P, Hardman Julian, Moore Nina Z, Hussain M Shazam, Bain Mark D, Rasmussen Peter A, Masaryk Thomas J, Elgabaly Mohammed H, Sheikhi Lila, Toth Gabor

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

The low-profile Neuroform Atlas stent received FDA Humanitarian Device Exemption status (HDE) in January 2018 for stent-assisted coil embolization of wide-necked saccular aneurysms. We review and report our results with the Atlas stent in our institution within the first year after its HDE approval.

METHODS

Our retrospective chart review identified patients treated with the Atlas stent. We analyzed the patient demographics, aneurysm characteristics, stent parameters and configuration, complications, angiographic, and clinical outcomes at discharge.

RESULTS

From January to December 2018, 76 Atlas stents were deployed in 58 patients (average 1.3 stents/patient). Median patient age was 63.5 (IQR 56-71) years. Fifty-six (96.6%) patients had elective embolization of unruptured aneurysms, while two (3.4%) patients underwent embolization of a ruptured aneurysm within 2 weeks of subarachnoid hemorrhage. Forty (69.0%) patients were treated with a single stent, 15 (25.9%) with a Y-stent, and three (5.2%) with X-stent configuration. All stent deployments were technically successful. Most stents (82.9%) were the smallest 3 mm diameter devices. Procedural complications included transient stent-associated thrombosis in three (5.2%) patients and aneurysm rupture in one (1.7%). None had distal embolization, associated cerebral infarction, or permanent neurological deficits. Immediate Raymond-Roy 1 occlusion was achieved in 41 (70.7%) patients. Median hospital length of stay for elective aneurysm embolization was 1 day. Excellent outcomes with median National Institute of Health Stroke Scale score 0 (IQR 0-0) and modified Rankin Score 0 (IQR 0-1) were seen for elective patients at discharge.

CONCLUSION

The Neuroform Atlas stent provided a reliable technical and safety profile for the treatment of intracranial wide-neck aneurysms. Further experience is needed to determine long-term durability and safety of this device.

Для цитирования: Tsai Jenny P, Hardman Julian, Moore Nina Z, Hussain M Shazam, Bain Mark D, Rasmussen Peter A, Masaryk Thomas J, Elgabaly Mohammed H, Sheikhi Lila, Toth Gabor. Early post-Humanitarian Device Exemption experience with the Neuroform Atlas stent.. Journal of neurointerventional surgery. 2019. DOI: 10.1136/neurintsurg-2019-014874.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.