MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1210/clinem/dgab536

Медицинская библиотека · The Journal of clinical endocrinology and metabolism · 2021

International Multicenter Validation Study of the SAGIT® Instrument in Acromegaly.

Giustina Andrea, Bronstein Marcello D, Chanson Philippe, Petersenn Stephan, Casanueva Felipe F, Sert Caroline, Houchard Aude, Melmed Shlomo

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод пока не подготовлен

Аннотация

CONTEXT: The SAGIT® instrument (SAGIT) has been developed to enable accurate characterization of acromegaly disease activity.

OBJECTIVE

We evaluated the ability of SAGIT to discriminate acromegaly disease control status.

METHODS

This multicenter, noninterventional, prospective and retrospective, longitudinal study, conducted at academic and private clinical practice sites, included patients aged ≥ 18 years with a diagnosis of controlled (n = 109) or non-controlled (n = 105) acromegaly, assessed by clinical global evaluation of disease control (CGE-DC) questionnaire, investigator therapeutic decision, and international guidelines. Control status was not determined at baseline for 13 patients. Since 9 patients were enrolled retrospectively, all presented analyses are based on the prospective population (N = 227). Patients were assessed over a 2-year follow-up period. Classification and regression tree (CART) analyses were performed to investigate how SAGIT components at baseline (signs/symptoms [S], associated comorbidities [A], growth hormone levels [G], insulin-like growth factor 1 levels [I], tumor features [T]) discriminate between controlled and non-controlled acromegaly.

RESULTS

Baseline mean subscores S, G, I, and T were significantly lower in patients with CGE-DC controlled vs CGE-DC non-controlled acromegaly. SAGIT components I and G for CGE-DC and S, A, G, I, and T for the clinician's therapeutic decision were retained by CART analyses. For international guidelines, only SAGIT component I was retained. The risk for undergoing ≥ 1 treatment change during the study was 3.44 times greater for CGE-DC non-controlled acromegaly relative to CGE-DC controlled acromegaly.

CONCLUSION

The SAGIT instrument is a valid and sensitive tool to comprehensively and accurately assess acromegaly severity.

Для цитирования: Giustina Andrea, Bronstein Marcello D, Chanson Philippe, Petersenn Stephan, Casanueva Felipe F, Sert Caroline, Houchard Aude, Melmed Shlomo. International Multicenter Validation Study of the SAGIT® Instrument in Acromegaly.. The Journal of clinical endocrinology and metabolism. 2021. DOI: 10.1210/clinem/dgab536.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.